Dataset Open Access
Mathieu Gaborit;
Luc Jaouen;
Olivier Dazel;
Peter Göransson
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="DOI">10.5281/zenodo.3358921</identifier> <creators> <creator> <creatorName>Mathieu Gaborit</creatorName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0001-9071-6325</nameIdentifier> <affiliation>LAUM UMR CNRS 6613, Le Mans Université, Le Mans, France & MWL, KTH Royal Institute of Technology, Stockholm, Sweden</affiliation> </creator> <creator> <creatorName>Luc Jaouen</creatorName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-3141-800X</nameIdentifier> <affiliation>Matelys Research Lab, Vaulx-en-Velin, France</affiliation> </creator> <creator> <creatorName>Olivier Dazel</creatorName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-0534-000X</nameIdentifier> <affiliation>LAUM UMR CNRS 6613, Le Mans Université, Le Mans, France</affiliation> </creator> <creator> <creatorName>Peter Göransson</creatorName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0003-2393-4204</nameIdentifier> <affiliation>MWL, KTH Royal Institute of Technology, Stockholm, Sweden</affiliation> </creator> </creators> <titles> <title>Statistical characterisation and responses of acoustic screens and two-layers systems</title> </titles> <publisher>Zenodo</publisher> <publicationYear>2019</publicationYear> <subjects> <subject>acoustic films</subject> <subject>impedance tube measurement</subject> <subject>characterisation</subject> <subject>equivalent fluid model</subject> </subjects> <dates> <date dateType="Issued">2019-08-02</date> </dates> <language>en</language> <resourceType resourceTypeGeneral="Dataset"/> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/3358921</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.3358920</relatedIdentifier> </relatedIdentifiers> <version>1.0</version> <rightsList> <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract"><p>The present dataset contains measurements of the acoustic response of screens in an impedance tube with different backings. It includes as well the characterised parameters for the screens and backings.</p> <p><strong>License</strong></p> <p>This dataset is released under Creative Commons with Attribution (CC BY). Any reutilisation of the present dataset in scholarly works must properly cite this work and its authors:</p> <pre><code>Statistical characterisation and responses of acoustics screens and two-layers systems M. Gaborit, L. Jaouen, O. Dazel, P. Göransson DOI: 10.5281/zenodo.3358921 </code></pre> <p><strong>Protocol</strong></p> <p>Two different films (one woven and one non-woven) were sampled 40 times in order to characterise their parameters in an impedance tube. Sampling is manual, the tube inner diameter is 44.44mm and the samples are cut to a slightly large size in order to be clamped inside the tube for measurements.</p> <p>The films are tested in different configurations including some with backings. Two types of backings are considered (melamine and glass wool). These backings are also characterised using 3 and 2 samples respectively. When measuring the response of the film on a backing only 20 samples of each film were used.</p> <p>All measurements span the [4, 4520] Hz band. The setup is calibrated anew before each measurement session.</p> <p><strong>Films&#39; characterisation</strong></p> <p>The films are clamped in the seam between the two parts of the tube, a 200mm air plenum is formed downstream and ends with a rigid backing. The samples for each type of film are measured within 4h.</p> <p>The characterisation procedure implements the method described in the following reference:</p> <ul> <li>Jaouen L. B&eacute;cot F.-X. JASA 129(3) pp. 1400 - 1406, 2011</li> </ul> <p><strong>Backings&#39; characterisation</strong></p> <p>The sample and backing piston are placed to give a rigid backing and have the sample&#39;s surface flush with the seam between the two parts of the tube. In the case of the glass wool, the material has a slight (below millimetre) embossing and the supporting surface is placed flush with respect to the seam (the top of the embossing is not considered as the sample surface).</p> <p>The characterisation procedure implements the method described in the following references:</p> <ul> <li>Olny, X. &amp; Panneton, R. JASA 123(2) pp. 814 &ndash; 824, 2008</li> <li>Panneton R. &amp; Olny, X. JASA 119(4), p. 2027, 2006</li> </ul> <p><strong>Response measurements</strong></p> <p>To measure responses of the film/backing systems, the backing are placed as described in the previous paragraph. The film is clamped in the seam as described in the &quot;Films&#39; characterisation&quot; section. A plastic grid with thin struts is placed upstream to prevent the film from bending. This setup allows for easily changing the film without replacing the backing sample. Films&#39; samples 1 to 20 are used for response measurements. Measurement of the grid response on a rigid backing and an air plenum of 200mm are provided for reference.</p> <p><strong>Hardware</strong></p> <ul> <li><a href="http://www.mecanum.com/en/products/impedance-tube/impedance-and-transmission-tube-3-mic/">Mecanum 3-microphones tube, diameter: 44.44mm</a></li> </ul> <p><strong>Software</strong></p> <ul> <li><a href="http://tubecell.matelys.com/">Matelys TubeCell</a> (rig control)</li> <li><a href="http://rokcell.matelys.com/">Matelys RoKCell</a> (characterisation)</li> </ul> <p>The piece of software controlling the rig implements a 3-microphones technique described in the following references:</p> <ul> <li>Iwase T. Izumi Y. J. Acoust. Soc. Jpn J 52(6) pp. 411&ndash;419, 1996 (in Japanese)</li> <li>Iwase T. Izumi Y. Kawabata R. in proc. Internoise, 1998 (Christchurch, New Zealand)</li> </ul> <p><strong>Structure of the datasets and files</strong></p> <p>The present dataset comprises two parts. The actual traces and associated measurement parameters as exported from TubeCell are found in the directory <code>measurements</code>. The results from the characterisation process as exported with RoKCell are in the <code>characterisations</code> folder. These results were augmented with direct measurements of the weights and thickness of the samples (both for the films and the backings).</p> <p><strong>Measurements</strong></p> <p>The measurements are stored in the <code>measurements</code> directory. There are several sub-directory for each of the measurement sessions:</p> <ul> <li><code>backings</code>: measurements for the caracterisation of the two backings (all samples, with and without grid)</li> <li><code>grid</code>: measurements of the grid alone on a rigid backing and with a 200mm air plenum</li> <li><code>nonwoven_alone</code>: measurements for the caracterisation of the non-woven film on a 200mm air plenum, no grid (all 40 samples)</li> <li><code>woven_alone</code>: measurements for the caracterisation of the woven film on a 200mm air plenum, no grid (all 40 samples)</li> <li><code>nonwoven_on_glasswool</code>: measurements of the response of 20 non-woven film samples clamped with a grid upstream and the same glass wool sample downstream on a rigid backing</li> <li><code>nonwoven_on_melamine</code>: measurements of the response of 20 non-woven film samples clamped with a grid upstream and the same melamine sample downstream on a rigid backing</li> <li><code>woven_on_glasswool</code>: measurements of the response of 20 woven film samples clamped with a grid upstream and the same glass wool sample downstream on a rigid backing</li> <li><code>woven_on_melamine</code>: measurements of the response of 20 woven film samples clamped with a grid upstream and the same melamine sample downstream on a rigid backing</li> </ul> <p>Each measurement is stored into a <code>.irk</code> <em>and</em> a <code>.rok</code> file. The first one contains some meta-data on the measurement process, the second contains the actual traces.</p> <p><strong>Structure of irk files</strong></p> <p>The <code>.irk</code> files contain the following meta-data:</p> <ul> <li>Date</li> <li>Medium ID</li> <li>Thickness</li> <li>Size of the air plenum</li> <li>Measure parameter l</li> <li>Measure parameter s</li> <li>Sampling frequency</li> <li>Tube radius [m]</li> <li>Average 1</li> <li>Average 2</li> <li>Temperature [&deg;C]</li> <li>Atmospheric pressure [Pa]</li> <li>Humidity [%]</li> <li>High cut-off frequency (generator) [Hz]</li> <li>Low cut-off frequency (generator) [Hz]</li> <li>Position of the cavity microphone</li> <li>Comments</li> </ul> <p><strong>Structure of rok files</strong></p> <p>The <code>.rok</code> files contain the following vector (column-major). The first line is to be omitted when reading the files, it contains the columns title. The columns are these:</p> <ul> <li>Frequency (Hz)</li> <li>Absorption coefficient</li> <li>Real part of the reflection coefficient</li> <li>Imaginary part of the reflection coefficient</li> <li>Real part of the normalised surface impedance</li> <li>Imaginary part of the normalised surface impedance</li> <li>Real part of the transfer function</li> <li>Imaginary part of the transfer function</li> <li>Real part of the normalised density</li> <li>Imaginary part of the normalised density</li> <li>Real part of the normalised compressibility</li> <li>Imaginary part of the normalised compressibility</li> <li>... frequency response functions used to compute the previous quantities</li> </ul> <p><strong>Characterisations</strong></p> <p>The directory <code>characterisations</code> contains YAML 1.2 files created from the output files of the characterisation software, exploiting the measurement data. There are three subdirectories:</p> <ul> <li><code>backings</code> contains the characterisation of the backings (each sample and an average file)</li> <li><code>nonwoven</code> contains the characterisation of the non-woven film (each sample and an average file)</li> <li><code>woven</code> contains the characterisation of the woven film (each sample and an average file)</li> </ul> <p><strong>More information</strong></p> <p>For further inquiry write to gaborit at kth dot se</p></description> </descriptions> </resource>
All versions | This version | |
---|---|---|
Views | 127 | 93 |
Downloads | 21 | 16 |
Data volume | 468.1 MB | 348.0 MB |
Unique views | 106 | 80 |
Unique downloads | 16 | 12 |