Dataset Open Access

WWBS Metrics

Roberto Orselli


JSON Export

{
  "files": [
    {
      "links": {
        "self": "https://zenodo.org/api/files/d14f2c20-c839-4a35-aa2f-29c7898e6ade/WWBS%20Metrics%20Datasets.rar"
      }, 
      "checksum": "md5:10ff41bb8abe0084fbe993a9ed2b4840", 
      "bucket": "d14f2c20-c839-4a35-aa2f-29c7898e6ade", 
      "key": "WWBS Metrics Datasets.rar", 
      "type": "rar", 
      "size": 1086722597
    }
  ], 
  "owners": [
    66605
  ], 
  "doi": "10.5281/zenodo.2671608", 
  "stats": {
    "version_unique_downloads": 17.0, 
    "unique_views": 83.0, 
    "views": 108.0, 
    "downloads": 24.0, 
    "unique_downloads": 17.0, 
    "version_unique_views": 83.0, 
    "volume": 26081342328.0, 
    "version_downloads": 24.0, 
    "version_views": 108.0, 
    "version_volume": 26081342328.0
  }, 
  "links": {
    "doi": "https://doi.org/10.5281/zenodo.2671608", 
    "conceptdoi": "https://doi.org/10.5281/zenodo.2671607", 
    "bucket": "https://zenodo.org/api/files/d14f2c20-c839-4a35-aa2f-29c7898e6ade", 
    "conceptbadge": "https://zenodo.org/badge/doi/10.5281/zenodo.2671607.svg", 
    "html": "https://zenodo.org/record/2671608", 
    "latest_html": "https://zenodo.org/record/2671608", 
    "badge": "https://zenodo.org/badge/doi/10.5281/zenodo.2671608.svg", 
    "latest": "https://zenodo.org/api/records/2671608"
  }, 
  "conceptdoi": "10.5281/zenodo.2671607", 
  "created": "2019-05-07T14:37:54.117180+00:00", 
  "updated": "2019-11-01T07:11:43.288164+00:00", 
  "conceptrecid": "2671607", 
  "revision": 7, 
  "id": 2671608, 
  "metadata": {
    "access_right_category": "success", 
    "doi": "10.5281/zenodo.2671608", 
    "description": "<p>The dataset consists of recordings acquired from a sensorized WWBS smart-vest garment (developed by the project&#39;s partner SMARTEX), which the older adults wear during their daily routine.</p>\n\n<p>The garment is equipped with electrodes for ECG monitoring, a piezoresistive sensor for respiration monitoring, and Inertial Measurement Units (IMUs) for movement and posture monitoring.</p>\n\n<p>Each recording consists of a series of channels, and each recording channel is a pair of [Timestamp, Value] columns.</p>\n\n<p>The full list of recording channels is described below:</p>\n\n<p><strong>- Part_id</strong>: User ID, a 4-digit number, serving as the file name for each user&#39;s data</p>\n\n<p>- <strong>ECG</strong>: Electric signal measuring the ECG (value: 0.8 mV - sampling rate: 250Hz)</p>\n\n<p>- <strong>ECGquality</strong>: ECG signal quality (value: 0-255 where 0=poor and 255=excellent - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>ECGHR</strong>: Heart rate (value: Beats/minute - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>ECGRR</strong>: R-R intervals (value: number of samples between R-R peaks - sampling rate:1/5 sec)</p>\n\n<p>- <strong>ECGHRV</strong>: Heart rate variability (value: ms - sampling rate: 1/60 sec)</p>\n\n<p>- <strong>AccX-Y-Z</strong>: Accelerometer in X-Y-Z axes (value: 0.97 10-3 g - sampling rate: 25 Hz)</p>\n\n<p>- <strong>GyroX-Y-Z</strong>: Gyroscope in X-Y-Z axes (value: 0.122 &deg;/s - sampling rate: 25 Hz)</p>\n\n<p>- <strong>MagX-Y-Z</strong>: Magnetometer in X-Y-Z axes (value: 0.6 &micro;T - sampling rate: 25 Hz)</p>\n\n<p>- <strong>RespPiezo</strong>: Electric signal measuring the chest pressure on the piezoelectric point (value: 0.8 mV - sampling rate: 25 Hz)</p>\n\n<p>- <strong>RespQuality</strong>: Respiration signal quality (value: 0-255 where 0=poor and 255=excellent - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>BR</strong>: Breathing rate (value: Breaths/minute - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>BA</strong>: Breathing Amplitude (value: logic levels - sampling rate: 1/15 sec)</p>\n\n<p>- <strong>Activityenergy</strong>: estimation of energy activity (value: estimation where 0=no activity and 255=max of activity - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>Activityclass</strong>: Activity performed (value: 0-4 where 0=other, 1=lying, 2=standing/sitting, 3=walking and 4=running - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>Activity1Pace</strong>: Step period (value: ms- sampling rate: 1 Hz)</p>\n\n<p>- <strong>ActivityPace</strong>: Pace (value: steps/min - sampling rate: 1/5 sec)</p>\n\n<p>- <strong>Q0-Q1-Q2-Q3</strong>: Quaternions from main electronic device, i.e. Q0, Q1, Q2, Q3 components (value: Q14 format - sampling rate: 25 Hz)</p>\n\n<p>- <strong>QEL0-QEL1-QEL2-QEL3</strong>: Quaternions from external left arm device, i.e. Q0, Q1, Q2, Q3 components (value: Q14 format - sampling rate: 25 Hz)</p>\n\n<p>- <strong>QER0-QER1-QER2-QER3</strong>: Quaternions from external right arm device, i.e. Q0, Q1, Q2, Q3 components (value: Q14 format - sampling rate: 25 Hz)</p>", 
    "contributors": [
      {
        "affiliation": "University of Patras", 
        "type": "DataCollector", 
        "name": "John Ellul"
      }, 
      {
        "affiliation": "Materia Groupd Cyprus", 
        "type": "DataCollector", 
        "name": "Marina Polycarpou"
      }, 
      {
        "affiliation": "INSERM France", 
        "type": "DataCollector", 
        "name": "Marina Kotsani"
      }, 
      {
        "affiliation": "University of Patras", 
        "type": "DataCurator", 
        "name": "Evangelia I. Zacharaki"
      }
    ], 
    "title": "WWBS Metrics", 
    "license": {
      "id": "CC-BY-4.0"
    }, 
    "relations": {
      "version": [
        {
          "count": 1, 
          "index": 0, 
          "parent": {
            "pid_type": "recid", 
            "pid_value": "2671607"
          }, 
          "is_last": true, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "2671608"
          }
        }
      ]
    }, 
    "grants": [
      {
        "code": "690140", 
        "links": {
          "self": "https://zenodo.org/api/grants/10.13039/501100000780::690140"
        }, 
        "title": "Sensing and predictive treatment of frailty and associated co-morbidities using advanced personalized patient models and advanced interventions", 
        "acronym": "FrailSafe", 
        "program": "H2020", 
        "funder": {
          "doi": "10.13039/501100000780", 
          "acronyms": [
            "EC"
          ], 
          "name": "European Commission", 
          "links": {
            "self": "https://zenodo.org/api/funders/10.13039/501100000780"
          }
        }
      }
    ], 
    "keywords": [
      "sensorized garment", 
      "WWBS metrics", 
      "smart vest recordings", 
      "ECG electrode monitoring", 
      "respiration monitoring via piezoresistive sensor", 
      "movement and posture monitoring"
    ], 
    "publication_date": "2019-05-07", 
    "creators": [
      {
        "affiliation": "SMARTEX", 
        "name": "Roberto Orselli"
      }
    ], 
    "access_right": "open", 
    "resource_type": {
      "type": "dataset", 
      "title": "Dataset"
    }, 
    "related_identifiers": [
      {
        "scheme": "doi", 
        "identifier": "10.5281/zenodo.2671607", 
        "relation": "isVersionOf"
      }
    ]
  }
}
108
24
views
downloads
All versions This version
Views 108108
Downloads 2424
Data volume 26.1 GB26.1 GB
Unique views 8383
Unique downloads 1717

Share

Cite as