Dataset Open Access

Penthera 3T

Paquette, Michael; Gilbert, Guillaume; Descoteaux, Maxime


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="DOI">10.5281/zenodo.2602049</identifier>
  <creators>
    <creator>
      <creatorName>Paquette, Michael</creatorName>
      <givenName>Michael</givenName>
      <familyName>Paquette</familyName>
      <affiliation>Sherbrooke Connectivity Imaging Lab (SCIL), Computer Science Department, Faculty of Science, Université de Sherbrooke, Sherbrooke, QC, Canada</affiliation>
    </creator>
    <creator>
      <creatorName>Gilbert, Guillaume</creatorName>
      <givenName>Guillaume</givenName>
      <familyName>Gilbert</familyName>
      <affiliation>MR Clinical Science, Philips Healthcare, Markham, ON, Canada</affiliation>
    </creator>
    <creator>
      <creatorName>Descoteaux, Maxime</creatorName>
      <givenName>Maxime</givenName>
      <familyName>Descoteaux</familyName>
      <affiliation>Sherbrooke Connectivity Imaging Lab (SCIL), Computer Science Department, Faculty of Science, Université de Sherbrooke, Sherbrooke, QC, Canada</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Penthera 3T</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2019</publicationYear>
  <dates>
    <date dateType="Issued">2019-03-21</date>
  </dates>
  <resourceType resourceTypeGeneral="Dataset"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/2602049</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.5281/zenodo.2602048</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights>
    <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;Penthera 3T: The acquisitions were done by the Sherbrooke Connectivity Imaging Lab in 2016. Thirteen young and healthy subjects (three women and ten men, mean of 25.92 (+-1.85) years old) were scanned six times: two sessions with three scans per session. The DWI (112x112 matrix, TR 5615 ms, TE 95 ms, SENSE factor of 2) were acquired on a 3 Tesla MRI (Philips, Ingenia) with a single-shot echo-planar imaging sequence having 3 different shells, b=300, 1000, 2000 mm&lt;sup&gt;2&lt;/sup&gt;/s with respectively 8, 32 and 60 directions distributed, 7 b=0 mm&lt;sup&gt;2&lt;/sup&gt;/s for a total of 107 images and a 2 mm isotropic spatial resolution. A reversed phase encoded b=0 image is available, to correct EPI distortions, with the same spatial resolution as the DWI. The T1-weighted MPRAGE image (TR 7.9 ms, TE 3.5 ms) has a 1mm isotropic spatial resolution.&lt;/p&gt;</description>
  </descriptions>
</resource>
462
70
views
downloads
All versions This version
Views 462460
Downloads 7070
Data volume 170.5 GB170.5 GB
Unique views 413411
Unique downloads 6767

Share

Cite as