RF sensing
THz
mm-wave
<p>The objective of this study is to investigate the possibility to detect mental and light physical stress through the measurement of skin reflectance in the mm-wave/sub-THz band. Two frequency bands have been considered, 75-110 GHz (Band-I) and 325-500 GHz (Band-II), while the measurements have been performed in the three different locations, the arm, the dorsal side of the hand and the fingertip.</p>
<p>Each transmitter and receiver set is equipped with a matched standard horn antenna operated at the selected frequency band.</p>
<p>The transmitter and receiver used during the test are active mixers. To operate each active module a local oscillator (LO) is required. The PXA and the Agilent generators are used as LO for transmitter (TX) and receiver (RX) accordingly (Fig. 2). The output signal from the receiver (RX) is gathered by a spectrum analyzer and then post-processed. The entire lab bench is connected through GPIB and both LO generators are synchronized (10MHz).</p>
<p>The measured reflected signal amplitude is recorded and post-process on a personal computer.</p>
<p>The dataset refers to Laboratory test. The skin reflectance was measured during rest and after mental and physical stress. Physical stress was provoked using a dynamometer under 15 N of force for 5 minutes. Provocation of mental stress was achieved with the use of the Stroop Test [11] for 15 minutes. A stress measurement was always preceded by a resting period of at least 15 minutes. Three hand locations have been considered, (a) arm, (b) hand and (c) finger.</p>
<p>The datasets are related to the open accessible publication "<strong>Human Physical Condition RF Sensing at THz range".</strong></p>
Zenodo
2016-09-14
info:eu-repo/semantics/other
645483
user-m3tera
user-eu
award_title=Micromachined terahertz systems -a new heterogeneous integration platform enabling the commercialization of the THz frequency spectrum; award_number=644039; award_identifiers_scheme=url; award_identifiers_identifier=https://cordis.europa.eu/projects/644039; funder_id=00k4n6c32; funder_name=European Commission;
1579893890.864849
721
md5:6231094a4b9a4a8452a0449f3c0e46cc
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_7.txt
762
md5:c3e3d8814fbd2d34960ef6f186a13d59
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_10.txt
1732
md5:ab6fdae87dc92e7c85b9393aaf5ce1b8
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_8.txt
3841
md5:70c280daeeac5a02957a455f1b1e990c
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_5_.txt
3114
md5:32e0a8b805de19b901903c6146fbc91f
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_5.txt
885
md5:007678d94dcd74f46b77ab6ff8838437
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_9.txt
2667
md5:64136824f6c0915077bf999d112bad16
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_6.txt
770
md5:2e7180dce0f01150bc85a7ae415df778
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_7_.txt
4215
md5:c3645517c40d1d1c8cf398b63c6e671e
https://zenodo.org/records/154032/files/CSEM-EMBC-Fig_4.txt
public
10.5281/zenodo.154031
Is supplement to
doi
isVersionOf
doi