Design of Air Conditioning Automation for Patisserie Shopwindow

Description

Having done in this study, air-conditioning
automation for patisserie shopwindow was designed. In the cooling
sector it is quite important to cooling up the air temperature in the
shopwindow within short time interval. Otherwise the patisseries
inside of the shopwindow will be spoilt in a few days. Additionally
the humidity is other important parameter for the patisseries kept in
shopwindow. It must be raised up to desired level in a quite short
time. Traditional patisserie shopwindows only allow controlling
temperature manually. There is no humidity control and humidity is
supplied by fans that are directed to the water at the bottom of the
shopwindows. In this study, humidity and temperature sensors
(SHT11), PIC, AC motor controller, DC motor controller, ultrasonic
nebulizer and other electronic circuit members were used to simulate
air conditioning automation for patisserie shopwindow in proteus
software package. The simulation results showed that temperature
and humidity values are adjusted in desired time duration by openloop
control technique. Outer and inner temperature and humidity
values were used for control mechanism.