Dataset Open Access

3D Dataset "Computation of Exact g-Factor Maps in 3D GRAPPA Reconstructions"

Rabanillo, Iñaki; Zhu, Ante; Aja-Fernández, Santiago; Alberola-López, Carlos; Hernando, Diego


JSON-LD (schema.org) Export

{
  "description": "<p>Datasets used in the paper entitled &quot;&quot;, containing the following acquisitions:</p>\n\n<p>&nbsp;&nbsp;&nbsp; <strong>1) Simulated abdomen data set</strong>: we have synthetized a 3D volume using the simulation environment XCAT based on the extended cardio-torso phantom. We simulated a T1-weighted acquisition using the following acquisition parameters: TE/TR=1.5/3ms, flip angle=60&ordm;, acquisition matrix size=60x60x32. A 32-coil acquisition was simulated by modulating the image using artificial sensitivity maps coded for each coil. The noise-free coil images were transformed into the \\bk--space and corrupted with synthetic Gaussian noise characterized by the matrices <span class=\"math-tex\">\\(\\Gamma_k\\)</span>and&nbsp;<span class=\"math-tex\">\\(C_k\\)</span> with SNR=25 for each coil, and the correlation coefficient between coils was set to <span class=\"math-tex\">\\(\\rho\\)</span>=0.1$. For statistical purposes, 4000 realizations of each image were used.</p>\n\n<p><br>\n&nbsp;&nbsp;&nbsp; <strong>2) Water phantom acquisition</strong>: A MR phantom sphere with solution (GE Medical Systems, Milwaukee, WI) was scanned in a 32-channel head coil on a 3.0T scanner (MR750, GE Healthcare, Waukesha, WI). A spoiled gradient-echo acquisition with 100 realizations of the same fully-encoded k-space sampling was used. Acquisition parameters included: coronal view, TE/TR=0.96/3.69ms, flip angle=12&ordm;, field of view=22x22$x30.7<span class=\"math-tex\">\\(cm\u00b3\\)</span>, acquisition matrix size=60x60x32, bandwidth=62.5KHz. We corrected for <span class=\"math-tex\">\\(B_0\\)</span> field drift related phase variations and magnitude decay by a pre-processing step. First we estimated the phase-shift between realizations from the center of the k-space as a cubic function of time and removed it afterwards. And, second, we estimated the magnitude-decay in the k-space as a linear function and substracted it in order not to affect the noise.</p>\n\n<p><br>\n&nbsp;&nbsp;&nbsp; <strong>3) In vivo acquisition</strong>: in order to assess the feasibility of the proposed method, after obtaining the approval fo the local institutional review board (IRB), a volunteer was scanned in a 32-channel head coil on a 3.0T scanner (MR750, GE Healthcare, Waukesha, WI). A spoiled gradient-echo acquisition of a fully-encoded \\bk--space sampling was used. Acquisition parameters included: coronal view, TE/TR=2.2/5.7ms, flip angle=12&ordm;,field of view=22x22x22<span class=\"math-tex\">\\(cm\u00b3\\)</span>, matrix size=220x220x220, bandwidth=62.5$KHz.</p>", 
  "license": "http://creativecommons.org/licenses/by-sa/4.0/legalcode", 
  "creator": [
    {
      "affiliation": "Universidad de Valladolid", 
      "@id": "https://orcid.org/0000-0001-5309-6446", 
      "@type": "Person", 
      "name": "Rabanillo, I\u00f1aki"
    }, 
    {
      "affiliation": "University of Wisconsin-Madison", 
      "@type": "Person", 
      "name": "Zhu, Ante"
    }, 
    {
      "affiliation": "Universidad de Valladolid", 
      "@type": "Person", 
      "name": "Aja-Fern\u00e1ndez, Santiago"
    }, 
    {
      "affiliation": "Universidad de VAlladolid", 
      "@type": "Person", 
      "name": "Alberola-L\u00f3pez, Carlos"
    }, 
    {
      "affiliation": "University of Wisconsin-Madison", 
      "@type": "Person", 
      "name": "Hernando, Diego"
    }
  ], 
  "url": "https://zenodo.org/record/1283312", 
  "datePublished": "2018-06-05", 
  "keywords": [
    "Phantom", 
    "MRI", 
    "Noise", 
    "GRAPPA", 
    "Parallel Imaging"
  ], 
  "@context": "https://schema.org/", 
  "distribution": [
    {
      "contentUrl": "https://zenodo.org/api/files/b2e6306c-a5b2-4365-933c-a66d65e4d2f7/Data3D.zip", 
      "@type": "DataDownload", 
      "fileFormat": "zip"
    }
  ], 
  "identifier": "https://doi.org/10.5281/zenodo.1283312", 
  "@id": "https://doi.org/10.5281/zenodo.1283312", 
  "@type": "Dataset", 
  "name": "3D Dataset \"Computation of Exact g-Factor Maps in 3D GRAPPA Reconstructions\""
}
41
7
views
downloads
All versions This version
Views 4141
Downloads 77
Data volume 131.7 GB131.7 GB
Unique views 3939
Unique downloads 77

Share

Cite as