Journal article Open Access

A Historically Significant Shield for In Vivo Measurements:

Lynch, Timothy P.


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="540" ind1=" " ind2=" ">
    <subfield code="u">https://creativecommons.org/publicdomain/zero/1.0/legalcode</subfield>
    <subfield code="a">Creative Commons Zero v1.0 Universal</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2007-08-01</subfield>
  </datafield>
  <controlfield tag="005">20200120171905.0</controlfield>
  <controlfield tag="001">1234849</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="o">oai:zenodo.org:1234849</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Due to the ubiquitous nature of ionizing radiation, in vivo measurement systems designed to measure low levels of radionuclides in people are usually enclosed within a high-density shield. Lead, steel, earth, and water are just some of the materials that have been and are being used to shield the detectors from radiations of cosmic, atmospheric, man-made, and terrestrial origin. At many Department of Energy sites, the counting room shields are constructed of pre-World War II steel to reduce the background levels in order to perform measurements that have low minimum detectable activities. The pre-World War II steel is commonly called low background steel in the in vivo industry vernacular. The low background descriptor comes from the fact the steel was manufactured prior to the beginning of atmospheric testing of nuclear weapons in the 1940's. Consequently, the steel is not likely to be contaminated with fission or activation products from fallout. For high energy photons (600 keV</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="s">655174</subfield>
    <subfield code="z">md5:d42aee98ef06d227d7bfc6f7a1cfb334</subfield>
    <subfield code="u">https://zenodo.org/record/1234849/files/article.pdf</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">open</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Lynch, Timothy P.</subfield>
  </datafield>
  <datafield tag="024" ind1=" " ind2=" ">
    <subfield code="a">10.1097/01.hp.0000259867.85459.b2</subfield>
    <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">A Historically Significant Shield for In Vivo Measurements:</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="7">
    <subfield code="a">cc-by</subfield>
    <subfield code="2">opendefinition.org</subfield>
  </datafield>
</record>
159
100
views
downloads
Views 159
Downloads 100
Data volume 65.5 MB
Unique views 157
Unique downloads 99

Share

Cite as