Published January 20, 2013 | Version 5490
Journal article Open

Overview of CARDIOSENSOR Project on the Development of a Nanosensor for Assessing the Risk of Cardiovascular Disease

Description

This paper aims at overviewing the topics of a research project (CARDIOSENSOR) on the field of health sciences (biomaterials and biomedical engineering). The project has focused on the development of a nanosensor for the assessment of the risk of cardiovascular diseases by the monitoring of C-reactive protein (CRP), which has been currently considered as the best validated inflammatory biomarker associated to cardiovascular diseases. The project involves tasks such as: 1) the development of sensor devices based on field effect transistors (FET): assembly, optimization and validation; 2) application of sensors to the detection of CRP in standard solutions and comparison with enzyme-linked immunosorbent assay (ELISA); and 3) application of sensors to real samples such as blood and saliva and evaluation of their ability to predict the risk of cardiovascular disease.

Files

5490.pdf

Files (651.7 kB)

Name Size Download all
md5:ce1a482b10975752e96ee751fec928b0
651.7 kB Preview Download

Additional details

References

  • S. Allender, P. Scarborough, V. Peto, M. Rayner, J. Leal, R. Luengo Fernandez, A. Gray, "European cardiovascular disease statistics - 2008", Health Econ., vol. 2008, p. 1-112, 2008.
  • V.L. Roger, A.S. Go, D.M. Lloyd-Jones, E.J. Benjamin, J.D. Berry, W.B. Borden, D.M. Bravata, S. Dai, E.S. Ford, C.S. Fox, H.J. Fullerton, C. Gillespie, S.M. Hailpern, J.A. Heit, V.J. Howard, B.M. Kissela, S.J. Kittner, D.T. Lackland, J.H. Lichtman, L.D. Lisabeth, D.M. Makuc, G.M. Marcus, A. Marelli, D.B. Matchar, C.S. Moy, D. Mozaffarian, M.E. Mussolino, G. Nichol, N.P. Paynter, E.Z. Soliman, P.D. Sorlie, N. Sotoodehnia, T.N. Turan, S.S. Virani, N.D.Wong, D. Woo, M.B. Turner, "Heart disease and stroke statistics - 2012 update. A report from the American Heart Association", Circulation, vol. 125, p. 2-220, 2012.
  • P.M. Ridker, "Clinical application of C-reactive protein for cardiovascular disease detection and prevention", Circulation, vol. 107, p. 363-369, 2003.
  • G.K. Hansson, "Inflammation, atherosclerosis, and coronary artery disease", N. Eng. J. Med., vol. 352, p. 1685-1695, 2005.
  • T. Vo-Dinh, B. Cullum, "Biosensors and biochips: advances in biological and medical diagnostics", Fresen. J. Anal. Chem., vol. 366, p. 540-551, 2000.
  • O. Rogowski, Y. Vered, I. Shapira, M. Hirsh, V. Zakut, S. Berliner, "Introducing the wide range C-reactive protein (wr-CRP) into clinical use for the detection of microinflammation", Clin. Chim. Acta, vol. 358, p. 151-158, 2005.
  • S.-C. Shiesh, T.-C. Chou, X.-Z. Lin, P.-C. Kao, "Determination of Creactive protein with an ultra-sensitivity immunochemiluminometric assay", J. Immunol. Methods, vol. 311, p. 87-95, 2006.
  • M.H.F. Meyer, M. Hartmann, H.J. Krause, G. Blankenstein, B. Mueller- Chorus, J. Oster, P. Miethe, M. Keusgen, "CRP determination based on a novel magnetic biosensor", Biosens. Bioelectron., vol. 22, p. 973-979, 2007.
  • S. Centi, L.B. Sanmartin, S. Tombelli, I. Palchetti, M. Mascini, " Detection of C-reactive protein (CRP) in serum by an electrochemical aptamer-based sandwich assay", Electroanalysis, vol. 21, p. 1309-1315, 2009. [10] N. Kim, D.-K. Kim, Y.-J. Cho, "Development of indirect competitive quartz crystal microbalance immunosensor for C-reactive protein", Sens. Actuators B, vol. 143, p. 444-448, 2009. [11] Y.-N. Yang, H.-I. Lin, J.-H. Wang, S.-C. Shiesh, G.-B. Lee, "An integrated microfluidic system for C-reactive protein measurement", Biosens. Bioelectron., vol. 24, p. 3091-3096, 2009. [12] A. Quershi, J.H. Niazi, S. Kallempudi, Y. Gurbuz, "Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays", Biosens. Bioelectron., vol. 25, p. 2318-2323, 2010. [13] M.T. Gomes, T.A.P. Rocha, A.C. Duarte, J.A.B.P. Oliveira, "The performance of a tetramethylammonium fluoride tetrahydrated coated piezoelectric crystal for carbon dioxide detection", Anal. Chim. Acta, vol. 355, p. 235-238, 1996. [14] T.A.P. Rocha, M.T. Gomes, A.C. Duarte, J.A.B.P. Oliveira, "Quartz crystal microbalance with gold electrodes as a sensor for monitoring gasphase adsorption/desorption of short chain alkylthiol and alkyl sulfides", Anal. Commun., vol. 35, p. 415-416, 1998. [15] L.I.B. Silva, T.A.P. Rocha-Santos, A.C. Duarte, "Development of a fluorosiloxane polymer coated optical fibre sensor for detection of organic volatile compounds", Sens. Actuators B., vol. 132, p. 280-289, 2008. [16] L.I.B. Silva, Rocha-Santos T.A.P., Duarte A.C., "Comparison of a gas chromatography-optical fibre (GC-OF) detector with a gas chromatography-flame ionization detector (GC-FID) for determination of alcoholic compounds in industrial atmospheres", Talanta, vol. 76, p. 395-399, 2008. [17] L.I.B. Silva, T.A.P. Rocha-Santos, A.C. Duarte, "Sensing of volatile organic compounds in indoor atmosphere and confined areas of industrial environments". Global NEST Journal, vol. 10, 217-225, 2008. [18] L.I.B. Silva, F.D.P. Ferreira, T.A.P. Rocha-Santos, A.C. Duarte, "Carbon nanotube field-effect transistor detector associated to gas chromatography for speciation of benzene, toluene, ethylbenzene, (o-, m- and p-)xylene", J. Chromatography A, vol. 1216, p. 6517-6521, 2009. [19] C.I.L. Justino, T.A.P. Rocha-Santos, A.C. Duarte, "Sampling and characterization of nanoaerosols in different environments". Trends Anal. Chem., vol. 30, p. 554-567, 2011. [20] L.I.B. Silva, C.I.L. Justino, I. Lopes, R. Pereira, A.C. Freitas, R. Calado, T.A.P. Rocha-Santos, T.S.L. Panteleitchouk, M.E. Pereira, A.C. Duarte, "Optical fiber based methodology for assessment of thiocyanate in seawater" J. Environ. Monitor., vol. 13, 6, 1811-1815, 2011. [21] C.I.L. Justino, A.C. Freitas, T.A.P. Rocha-Santos, A.C. Duarte, "Screening of single-walled carbon nanotubes by optical fiber sensing", Talanta, vol. 89, p. 105-108, 2012. [22] M.T. Gomes, T.A. Rocha, A.C. Duarte, J.A.B.P. Oliveira, "Determination of sulfur dioxide in wine using a quartz crystal microbalance". Anal. Chem., vol. 68, p. 1561-1564, 1996. [23] L.I.B. Silva, F.D.P. Ferreira, A.C. Freitas, T.A.P. Rocha-Santos, A.C. Duarte, "Optical fiber-based micro-analyzer for indirect measurements of volatile amines levels in fish". Food Chem., vol. 123, p. 806–813, 2010. [24] L.I.B. Silva, D. Rodrigues, A.C. Freitas, A.M. Gomes, T.A.P. Rocha- Santos, M.E. Pereira, A.C. Duarte, "Optical fibre based methodology for screening the effect of probiotic bacteria on conjugated linoleic acid (CLA) in curdled milk". Food Chem., vol. 127, p. 222-227, 2011. [25] L.I.B. Silva, F.D.P. Ferreira, A.C. Freitas, T.A.P. Rocha-Santos, A.C. Duarte, "Optical fiber biosensor coupled to chromatographic separation for screening of dopamine, norepinephrine and epinephrine in human urine and plasma", Talanta, vol. 80, p. 853-857, 2009. [26] F.D.P. Ferreira, L.I.B. Silva, A.C. Freitas, T.A.P. Rocha-Santos, A.C. Duarte, "High performance liquid chromatography coupled to an optical fibre detector coated with laccase for screening catecholamines in plasma and urine". J. Chromatography A., vol. 1216, p. 7049-7054, 2009. [27] C.I.L. Justino, T.A.P. Rocha-Santos, A.C. Duarte, "Review of analytical figures of merit of sensors and biosensors in clinical applications", Trends Anal. Chem., vol. 29, p. 1172-1183, 2010. [28] L.I.B. Silva, A.C. Freitas, T.A.P. Rocha-Santos, M.E. Pereira, A.C. Duarte, "Breath analysis by optical fiber sensor for the determination of exhaled organic compounds with a view to diagnostics". Talanta, vol. 83, p. 1586-1594, 2011. [29] L.I.B. Silva, A.M. Gomes, M.M. Pintado, H. Pinheiro, D. Moura, A.C. Freitas, T.A.P. Rocha-Santos, M.E. Pereira, A.C. Duarte, "Optical fiber bio-analyzer based on enzymatic coating matrix for catecholamines and their metabolites assessment in patients with Down syndrome". IEEE Sensors J., vol. 12, p. 76-84, 2012.