Journal article Closed Access

Energy Performance Analysis of the first Research-only Ground Coupled Heat Pump in Romania

Bendea, Codruta; Felea, Ioan; Bendea, Gabriel


MARC21 XML Export

<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
  <leader>00000nam##2200000uu#4500</leader>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2010-12-01</subfield>
  </datafield>
  <controlfield tag="005">20170906065141.0</controlfield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-ecfunded</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">user-zenodo</subfield>
  </datafield>
  <controlfield tag="001">1006</controlfield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="p">openaire</subfield>
    <subfield code="p">user-zenodo</subfield>
    <subfield code="p">user-ecfunded</subfield>
    <subfield code="o">oai:openaire.cern.ch:1006</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="4">
    <subfield code="c">57-62</subfield>
    <subfield code="n">4</subfield>
    <subfield code="p">Journal of sustainable energy</subfield>
    <subfield code="v">1</subfield>
    <subfield code="y">2010</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">One laboratory belonging to Energy
Engineering Faculty is heated with a ground-coupled
heat pump (GCHP) system having two types of
ground heat exchangers: a vertical one and a
horizontal one. This paper presents, at first, several
coefficients of performance that can be defined for
heat pumps together with their usability. Then, an
energy efficiency model is set specially for CGHP
systems. In this paper the simulation of energy
performances is done only for the vertical heat
exchanger (borehole heat exchanger) having two
configurations: single-U and double-U. All simulation
results range between normal values and can be
considered realistic.</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Faculty of Energy Engineering, University of Oradea</subfield>
    <subfield code="a">Felea, Ioan</subfield>
  </datafield>
  <datafield tag="700" ind1=" " ind2=" ">
    <subfield code="u">Faculty of Energy Engineering, University of Oradea</subfield>
    <subfield code="a">Bendea, Gabriel</subfield>
  </datafield>
  <datafield tag="542" ind1=" " ind2=" ">
    <subfield code="l">closed</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">publication</subfield>
    <subfield code="b">article</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="u">Faculty of Energy Engineering, University of Oradea</subfield>
    <subfield code="a">Bendea, Codruta</subfield>
  </datafield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">eng</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Energy Performance Analysis of the first Research-only Ground Coupled Heat Pump in Romania</subfield>
  </datafield>
  <datafield tag="536" ind1=" " ind2=" ">
    <subfield code="c">218895</subfield>
    <subfield code="a">Advanced ground source heat pump systems for heating and cooling in Mediterranean climate</subfield>
  </datafield>
</record>
20