Journal article Closed Access

Energy Performance Analysis of the first Research-only Ground Coupled Heat Pump in Romania

Bendea, Codruta; Felea, Ioan; Bendea, Gabriel


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="URL">https://zenodo.org/record/1006</identifier>
  <creators>
    <creator>
      <creatorName>Bendea, Codruta</creatorName>
      <givenName>Codruta</givenName>
      <familyName>Bendea</familyName>
      <affiliation>Faculty of Energy Engineering, University of Oradea</affiliation>
    </creator>
    <creator>
      <creatorName>Felea, Ioan</creatorName>
      <givenName>Ioan</givenName>
      <familyName>Felea</familyName>
      <affiliation>Faculty of Energy Engineering, University of Oradea</affiliation>
    </creator>
    <creator>
      <creatorName>Bendea, Gabriel</creatorName>
      <givenName>Gabriel</givenName>
      <familyName>Bendea</familyName>
      <affiliation>Faculty of Energy Engineering, University of Oradea</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Energy Performance Analysis of the first Research-only Ground Coupled Heat Pump in Romania</title>
  </titles>
  <publisher>Zenodo</publisher>
  <publicationYear>2010</publicationYear>
  <dates>
    <date dateType="Issued">2010-12-01</date>
  </dates>
  <language>en</language>
  <resourceType resourceTypeGeneral="Text">Journal article</resourceType>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://zenodo.org/record/1006</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsIdenticalTo"></relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://zenodo.org/communities/ecfunded</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://zenodo.org/communities/zenodo</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="info:eu-repo/semantics/closedAccess">Closed Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">One laboratory belonging to Energy
Engineering Faculty is heated with a ground-coupled
heat pump (GCHP) system having two types of
ground heat exchangers: a vertical one and a
horizontal one. This paper presents, at first, several
coefficients of performance that can be defined for
heat pumps together with their usability. Then, an
energy efficiency model is set specially for CGHP
systems. In this paper the simulation of energy
performances is done only for the vertical heat
exchanger (borehole heat exchanger) having two
configurations: single-U and double-U. All simulation
results range between normal values and can be
considered realistic.</description>
  </descriptions>
  <fundingReferences>
    <fundingReference>
      <funderName>European Commission</funderName>
      <funderIdentifier funderIdentifierType="Crossref Funder ID">10.13039/501100000780</funderIdentifier>
      <awardNumber awardURI="info:eu-repo/grantAgreement/EC/FP7/218895/">218895</awardNumber>
      <awardTitle>Advanced ground source heat pump systems for heating and cooling in Mediterranean climate</awardTitle>
    </fundingReference>
  </fundingReferences>
</resource>
21
0
views
downloads
Views 21
Downloads 0
Data volume 0 Bytes
Unique views 20
Unique downloads 0

Share

Cite as