MYCODO MANUAL



TABLE OF CONTENTS


About Mycodo

Frequently Asked Questions

Upgrading

Settings

-   General Settings
-   Relay Usage Settings
-   Users
-   User Roles
-   Alert Settings
-   Camera Settings

Controllers

-   Input
-   Output
-   PIDs
-   Timers
-   LCDs

Controller Functions

-   Conditional Statements
-   Methods

PID Tuning

-   PID Control Theory
-   Quick Setup Examples
-   Exact-Temperature Regulation
-   High-Temperature Regulation

Miscellaneous

-   Graphs
-   Camera
-   Relay Usage
-   System Backup
-   System Restore

Troubleshooting

-   Daemon Not Running
-   More

Sensor and Device Setup

Sensor Interfaces

-   1-Wire
-   GPIO
-   UART
-   I2C
-   Edge Detection

Device Setup

-   I2C Multiplexers
-   Analog to Digital Converters

Device Specific Information

Temperature Sensors

-   Raspberry Pi
-   Atlas Scientific PT-1000
-   DS18B20
-   TMP006, TMP007

Temperature, Humidity Sensors

-   AM2315
-   DHT11
-   DHT22, AM2302
-   HTU21D
-   SHT1x
-   SHT7x

CO2 Sensors

-   K-30
-   MH-Z19

Moisture Sensors

-   Chirp

pH Sensors

-   Atlas Scientific pH

Pressure Sensors

-   BME280
-   BMP085, BMP180

Luminosity Sensors

-   BH1750
-   TSL2561

Analog to Digital Converters

-   ADS1x15
-   MCP342x

Diagrams

-   DHT11 Diagrams
-   DS18B20 Diagrams
-   Raspberry Pi and Relay Diagrams

------------------------------------------------------------------------



ABOUT MYCODO


Mycodo is a remote monitoring and automated regulation system with a
focus on modulating environmental conditions. It was built to run on the
Raspberry Pi (versions Zero, 1, 2, and 3) and aims to be easy to install
and set up.

The core system coordinates a diverse set of responses to sensor
measurements, including actions such as camera captures, email
notifications, relay activation/deactivation, regulation with PID
control, and more. Mycodo has been used for cultivating gourmet
mushrooms, cultivating plants, culturing microorganisms, maintaining
honey bee apiary homeostasis, incubating snake eggs and young animals,
aging cheeses, fermenting foods, maintaining aquatic systems, and more.

A proportional-derivative-integral (PID) controller is a control loop
feedback mechanism used throughout industry for controlling systems. It
efficiently brings a measurable condition, such as the temperature, to a
desired state and maintains it there with little overshoot and
oscillation. A well-tuned PID controller will raise to the setpoint
quickly, have minimal overshoot, and maintain the setpoint with little
oscillation.



FREQUENTLY ASKED QUESTIONS


_Where do I even begin?_

Here is how I generally set up Mycodo to monitor and regulate:

1.  Determine what environmental condition you want to measure
    or regulate. Consider the devices that must be coupled to achieve
    this. For instance, temperature regulation require a temperature
    sensor and an electric heater and/or electric air conditioner.
2.  Determine what relays you will need to power your electric devices.
    The Raspberry Pi is capable of directly switching relays (using a
    3.3-volt signal), although opto-isolating the circuit is advisable.
    Be careful when selecting a relay not to exceed the current draw of
    the Raspberry Pi’s PGIO.
3.  See the Device Specific Information for information about what
    sensors are supported. Acquire one or more of these sensors and
    relays and connect them to the Raspberry Pi according to the
    manufacturer’s instructions.
4.  On the Sensors page, create a new sensor, using the dropdown to
    select the correct sensor. Configure the sensor with the correct
    communication pins, etc. and save. Activate the sensor to begin
    recording measurements.
5.  Go to the Data -> Live Measurements page to ensure there is recent
    data being acquired from the sensor.
6.  On the Relay -> Relays page, add a relay and configure the GPIO pin
    that switches it, whether the relay switches On when the signal is
    HIGH or LOW, and what state (On or Off) to set the relay when
    Mycodo starts.
7.  Test the relay by switching it On and Off from the Relay -> Relays
    page and make sure the device connected to the relay turns On when
    you select “On”, and Off when you select “Off”.
8.  On the PID -> PID Controllers page, create a PID controller with the
    appropriate sensor, measurement, relay, and other parameters. Refer
    to the Quick Setup Examples for setting up and tuning a
    PID controller.
9.  On the Data -> Live Graphs page, create a graph that includes the
    sensor measurement, the relay that is being used by the PID, and the
    PID setpoint. This provides a good visualization for tuning and
    adjusting the system.

------------------------------------------------------------------------

_Why is there only one FAQ?_

Good question.

------------------------------------------------------------------------



UPGRADING


If you already have Mycodo installed (version >= 4.0.0), you can perform
an upgrade to the latest release on github by either using the Upgrade
option in the web UI (recommended) or by issuing the following command
in a terminal. A log of the upgrade process is created at
/var/log/mycodo/mycodoupgrade.log

sudo /bin/bash ~/Mycodo/mycodo/scripts/upgrade_commands.sh upgrade



SETTINGS


The settings menu, accessed by selecting the gear icon in the top-right,
then the Configure link, is a general area for various system-wide
configuration options.


General Settings

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Language              Set the language that will be displayed in the
                        web user interface.

  Force HTTPS           Require web browsers to use SSL/HTTPS. Any
                        request to http:// will be redirected to
                        https://.

  Hide success alerts   Hide all success alert boxes that appear at the
                        top of the page.

  Hide info alerts      Hide all info alert boxes that appear at the
                        top of the page.

  Hide warning alerts   Hide all warning alert boxes that appear at the
                        top of the page.

  Opt-out of statistics Turn off sending anonymous usage statistics.
                        Please consider that this helps the development
                        to leave on.
  ---------------------------------------------------------------------


Relay Usage Settings

In order to calculate accurate relay usage statistics, a few
characteristics of your electrical system needs to be know. These
variables should describe the characteristics of the electrical system
being used by the relays to operate electrical devices. Note: Proper
relay usage calculations also rely on the correct current draw to be set
for each relay (see Relay Settings).

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Max Amps              Set the maximum allowed amperage to be switched
                        on at any given time. If a relay that’s
                        instructed to turn on will cause the sum of
                        active devices to exceed this amount, the relay
                        will not be allowed to turn on, to prevent any
                        damage that may result from exceeding current
                        limits.

  Voltage               Alternating current (AC) voltage that is
                        switched by the relays. This is usually 120 or
                        240.

  Cost per kWh          This is how much you pay per kWh.

  Currency Unit         This is the unit used for the currency that
                        pays for electricity.

  Day of Month          This is the day of the month (1-30) that the
                        electricity meter is read (which will
                        correspond to the electrical bill).
  ---------------------------------------------------------------------


Users

Mycodo requires at least one Admin user for the login system to be
enabled. If there isn’t an Admin user, the web server will redirect to
an Admin Creation Form. This is the first page you see when starting
Mycodo for the first time. After an Admin user has been created,
additional users may be created from the User Settings page.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Username              Choose a user name that is between 2 and 64
                        characters. The user name is case insensitive
                        (all user names are converted to lower-case).

  Email                 The email associated with the new account.

  Password/Repeat       Choose a password that is between 6 and 64
                        characters and only contain letters, numbers,
                        and symbols.

  Role                  Roles are a way of imposing access restrictions
                        on users, to either allow or deny actions. See
                        the table below for explanations of the four
                        default Roles.
  ---------------------------------------------------------------------


User Roles

Roles define the permissions of each user. There are 4 default roles
that determine if a user can view or edit particular areas of Mycodo.
Four roles are provided by default, but custom roles may be created.

  Role               Admin   Editor   Monitor   Guest
  ------------------ ------- -------- --------- -------
  Edit Users         X                          
  Edit Controllers   X       X                  
  Edit Settings      X       X                  
  View Settings      X       X        X         
  View Camera        X       X        X         
  View Stats         X       X        X         
  View Logs          X       X        X         

1The Edit Controllers permission protects the editing of Graphs, LCDs,
Methods, PIDs, Relays, Sensors, and Timers.

2The View Stats permission protects the viewing of usage statistics and
the System Info and Relay Usage pages.


Alert Settings

Alert settings set up the credentials for sending email notifications.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  SMTP Host             The SMTP server to use to send emails from.

  SMTP Port             Port to communicate with the SMTP server (465
                        for SSL, 587 for TSL).

  Enable SSL            Check to emable SSL, uncheck to enable TSL.

  SMTP User             The user name to send the email from. This can
                        be just a name or the entire email address.

  SMTP Password         The password for the user.

  From Email            What the from email address be set as. This
                        should be the actual email address for this
                        user.

  Max emails (per hour) Set the maximum number of emails that can be
                        sent per hour. If more notifications are
                        triggered within the hour and this number has
                        been reached, the notifications will be
                        discarded.

  Send Test Email       Test the email configuration by sending a test
                        email.
  ---------------------------------------------------------------------


Camera Settings

Many cameras can be used simultaneously with Mycodo. Each camera needs
to be set up in the camera settings, then may be used throughout the
software. Note that not every option (such as Hue or White Balance) may
be able to be used with your particular camera, due to manufacturer
differences in hardware and software.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Type                  Select whether the camera is a Raspberry Pi
                        Camera or a USB camera.

  Library               Select which library to use to communicate with
                        the camera. The Raspberry Pi Camera uses
                        picamera (and potentially opencv), and USB
                        cameras should be set to opencv.

  OpenCV Device         Any devices detected by opencv will populate
                        this dropdown list. If there are no values in
                        this list, none were detected. If you have
                        multiple opencv devices detected, try setting
                        the camera to each device and take a photo to
                        determine which camera is associated with which
                        device.

  Relay ID              This relay will turn on during the capture of
                        any still image (which includes timelapses).

  Rotate Image          The number of degrees to rotate the image.

  …                     Image Width, Image Height, Brightness,
                        Contrast, Exposure, Gain, Hue, Saturation,
                        White Balance. These options are
                        self-explanatory. Not all options will work
                        with all cameras.

  Pre Command           A command to execute (as user mycodo) before a
                        still image is captured.

  Post Command          A command to execute (as user mycodo) after a
                        still image is captured.

  Flip horizontally     Flip, or mirror, the image horizontally.

  Flip vertically       Flip, or mirror, the image vertically.
  ---------------------------------------------------------------------



CONTROLLERS


Controllers are essentially modules that can be used to perform
functions or communicate with other parts of Mycodo. Each controller
performs a specific task or group of related tasks. There are also
Controller Functions, which are larger functions of a controller or
controllers and have been given their own sections.


Input

Inputs (such as sensors or analog signals) measure environmental and
other characteristic conditions, which will be stored in an influxdb
round-robin database. This database will provide recent measurements for
Graphs, LCDs, PID Controllers, Conditional Statements, and other parts
of Mycodo to operate from.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Activate              After the sensor has been properly configured,
                        activation begins acquiring measurements from
                        the sensor. Any activated conditional
                        statements will now being operating.

  Deactivate            Deactivation stops measurements from being
                        acquired from the sensor. All associated
                        conditional statements will cease to operate.

  Save                  Save the current configuration entered into the
                        input boxes for a particular sensor.

  Delete                Delete a particular sensor.

  Up/Down               Move a particular sensor up or down in the
                        order displayed.

  Power Relay           Select a relay that powers the sensor. This
                        enables powering cycling (turn off then on)
                        when the sensor returns 3 consecutive errors to
                        attempt to fix the issue. Transistors may also
                        be used instead of a relay (note: NPN
                        transistors are preferred over PNP for powering
                        sensors).

  Location              Depending on what sensor is being used, you
                        will need to either select a serial number
                        (DS18B20 temperature sensor), a GPIO pin (in
                        the case of sensors read by a GPIO), or an I2C
                        address. and channel if using the TCA9548A I2C
                        multiplexer.

  I2C Bus               The bus to be used to communicate with the I2C
                        address. If you’re using an I2C multiplexer
                        that provides multiple buses, this allows you
                        to select which bus the sensor is connected to.

  Period                After the sensor is successfully read and a
                        database entry is made, this is the duration of
                        time waited until the sensor is measured again.

  Pre Relay             If you require a relay to be activated before a
                        measurement is made (for instance, if you have
                        a pump that extracts air to a chamber where the
                        sensor resides), this is the relay number that
                        will be activated. The relay will be activated
                        for a duration defined by the Pre Duration,
                        then once the relay turns off, a measurement by
                        the sensor is made.

  Pre Relay Duration    This is the duration of time that the Pre Relay
                        runs for before the sensor measurement is
                        obtained.

  Edge                  Edge sensors only: Select whether the Rising or
                        Falling (or both) edges of a changing voltage
                        are detected. A number of devices to do this
                        when in-line with a circuit supplying a
                        3.3-volt input signal to a GPIO, such as simple
                        mechanical switch, a button, a magnet
                        (reed/hall) sensor, a PIR motion detector, and
                        more.

  Bounce Time (ms)      Edge sensors only: This is the number of
                        milliseconds to bounce the input signal. This
                        is commonly called debouncing a signal. and may
                        be necessary if using a mechanical circuit.

  Reset Period          Edge sensors only: This is the period of time
                        after an edge detection that another edge will
                        not be recorded. This enables devices such as
                        PIR motion sensors that may stay activated for
                        longer periods of time.

  Multiplexer (MX)      If connected to the TCA9548A I2C multiplexer,
                        select what the I2C address of the multiplexer
                        is.

  Mx I2C Bus            If connected to the TCA9548A I2C multiplexer,
                        select the I2C bus the multiplexer is connected
                        to.

  Mx Channel            If connected to the TCA9548A I2C multiplexer,
                        select the channel of the multiplexer the
                        device is connected to.

  Measurement           Analog-to-digital converter only: The type of
                        measurement being acquired by the ADC. For
                        instance, if the resistance of a photocell is
                        being measured through a voltage divider, this
                        measurement would be “light”.

  Units                 Analog-to-digital converter only: This is the
                        unit of the measurement. With the above example
                        of “light” as the measurement, the unit may be
                        “lux” or “intensity”.

  Channel               Analog-to-digital converter only: This is the
                        channel to obtain the voltage measurement from
                        the ADC.

  Gain                  Analog-to-digital converter only: set the gain
                        when acquiring the measurement.

  Volts Min             Analog-to-digital converter only: What is the
                        minimum voltage to use when scaling to produce
                        the unit value for the database. For instance,
                        if your ADC is not expected to measure below
                        0.2 volts for your particular circuit, set this
                        to “0.2”.

  Volts Max             Analog-to-digital converter only: This is
                        similar to the Min option above, however it is
                        setting the ceiling to the voltage range. Units
                        Min Analog-to-digital converter only: This
                        value will be the lower value of a range that
                        will use the Min and Max Voltages, above, to
                        produce a unit output. For instance, if your
                        voltage range is 0.0 - 1.0 volts, and the unit
                        range is 1 - 60, and a voltage of 0.5 is
                        measured, in addition to 0.5 being stored in
                        the database, 30 will be stored as well. This
                        enables creating calibrated scales to use with
                        your particular circuit.

  Units Max             Analog-to-digital converter only: This is
                        similar to the Min option above, however it is
                        setting the ceiling to the unit range.
  ---------------------------------------------------------------------

Sensor Verification

Sensor verification was introduced in an earlier version and was broken
when the system moved to its new software framework. It was a great
feature, and it’s planned to be integrated into the latest version.

This allows the verification of a sensor’s measurement with another
sensor’s measurement. This feature is best utilized when you have two
sensors in the same location (ideally as close as possible). One sensor
(host) should be set up to use the other sensor (slave) to verify. The
host sensor should be used to operate the PID, as one feature of the
verification is the ability to disable the PID if the difference between
measurements is not within the range specified.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  GPIO                  This is the sensor that will be used to verify
                        the sensor measurement. The sensor will be read
                        directly after the first sensor’s measurement
                        to verify whether the sensors have similar
                        measurements.

  Difference            This is the maximum measured measurement
                        difference between the two sensors before an
                        action is triggered (either notify by email or
                        prevent PID from operating; more below).

  Notification          If the measurements of the two sensors differ
                        by more than the set _Difference_, an email
                        will be sent to the address in the
                        _Notification_ field.

  Stop PID              If the measurements of the two sensors differ
                        by more than the set _Difference_, the PID
                        controller will turn off.
  ---------------------------------------------------------------------


Output

PWM

Pulse-width modulation (PWM) is a modulation technique used to encode a
message into a pulsing signal, at a specific frequency in Hertz (Hz).
The average value of voltage (and current) fed to the load is controlled
by turning the switch between supply and load on and off at a fast rate.
The longer the switch is on compared to the off periods, the higher the
total power supplied to the load.

The PWM switching frequency has to be much higher than what would affect
the load (the device that uses the power), which is to say that the
resultant waveform perceived by the load must be as smooth as possible.
The rate (or frequency) at which the power supply must switch can vary
greatly depending on load and application, for example

  Switching has to be done several times a minute in an electric stove;
  120 Hz in a lamp dimmer; between a few kilohertz (kHz) to tens of kHz
  for a motor drive; and well into the tens or hundreds of kHz in audio
  amplifiers and computer power supplies.

The term duty cycle describes the proportion of ‘on’ time to the regular
interval or ‘period’ of time; a low duty cycle corresponds to low power,
because the power is off for most of the time. Duty cycle is expressed
in percent, 100% being fully on.

Currently, PWM is very new in Mycodo and does not have many features.
PWM pins can be set up in the Output -> Devices page, then it may be
used by a PWM PID Controller.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Library               Select the method for producing the PWM signal.
                        Hardware pins can produce up to a 30 MHz PWM
                        signal, while any other (non-hardware PWM) pin
                        can produce up to a 40 kHz PWM signal. See the
                        table, below, for the hardware pins on various
                        Pi boards.

  BCM Pin               This is the GPIO that will output the PWM
                        signal, using BCM numbering.

  Hertz                 This is frequency of the PWM signal.

  Duty Cycle            This is the proportion of the time on to the
                        time off, expressed in percent (0 - 100).

  Current Draw (amps)   This is the current draw, in amps, when the
                        duty cycle is 100%. Note: this value should be
                        calculated based on the voltage set in the
                        Relay Usage Settings.
  ---------------------------------------------------------------------

Non-hardware PWM Pins

If using any non-hardware PWM pin (see table below for hardware PWM
pins), then there are only certain frequencies that can be used. These
frequencies are 40000, 20000, 10000, 8000, 5000, 4000, 2500, 2000, 1600,
1250, 1000, 800, 500, 400, 250, 200, 100, and 50 Hz. If you attempt to
set a frequency that is not listed here, the nearest frequency from this
list will be used.

Hardware PWM Pins

The exact frequency may be set when using a hardware PWM pin. The same
PWM channel is available on multiple GPIO. The latest frequency and duty
cycle setting will be used by all GPIO pins which share a PWM channel.

  BCM Pin   PWM Channel   Raspberry Pi Version
  --------- ------------- ---------------------------
  12        0             All models except A and B
  13        1             All models except A and B
  18        0             All models
  19        1             All models except A and B
  40        0             Compute module only
  41        1             Compute module only
  45        1             Compute module only
  52        0             Compute module only
  53        1             Compute module only

Schematics for AC modulation

Below are hardware schematics that enable the modulation of alternating
current (AC) from the PWM output from Mycodo.

PWM output modulating alternating current (AC) at 1% duty cycle

[Schematic: PWM output modulating alternating current (AC) at 1% duty
cycle] 

PWM output modulating alternating current (AC) at 50% duty cycle

[Schematic: PWM output modulating alternating current (AC) at 50% duty
cycle] 

PWM output modulating alternating current (AC) at 99% duty cycle

[Schematic: PWM output modulating alternating current (AC) at 99% duty
cycle] 

Relays

Relays are electromechanical or solid-state devices that enable a small
voltage signal (such as from a microprocessor) to activate a much larger
voltage, without exposing the low-voltage system to the dangers of the
higher voltage.

Add and configure relays in the Relay tab. Relays must be properly set
up before PID regulation can be achieved.

Wired

To set up a wired relay, set the “GPIO Pin” to the BCM GPIO number of
each pin that activates each relay. _On Trigger_ should be set to the
signal that activates the relay (the device attached to vthe relay turns
on). If your relay activates when the potential across the coil is
0-volts, set _On Trigger_ to “Low”, otherwise if your relay activates
when the potential across the coil is 3.3-volts (or whatever switching
voltage you are using, if not being driven by the GPIO pin), set it to
“High”.

Wireless

Certain 433 MHz wireless relays may be used, however you will need to
set the pin of the transmitter (using WiringPi numbering), pulse length,
bit length, protocol, on command, and off command. To determine your on
and off commands, connect a 433 MHz receiver to your Pi, then run the
receiver script, below, and press one of the buttons (either on or off)
on your remote to detect the numeric code associated with that button.

sudo ~/Mycodo/env/bin/python ~/Mycodo/mycodo/devices/wireless_433mhz_pi_switch.py

433 MHz wireless relays have been successfully tested with SMAKN 433MHz
RF Transmitters/Receivers and Etekcity Wireless Remote Control
Electrical Outlets (see Issue 88 for more information). If you have a
433 MHz transmitter/receiver and a wireless relay that does not work
with the current code (even after trying several different protocol
settings), submit a new issue with details of your hardware.

Command

Another option for relay control is to execute a terminal command when
the relay is turned on or off. Commands will be executed as the user
‘mycodo’.

Wireless and Command Relay Note: Since the wireless protocol only allows
1-way communication to 433 MHz devices, wireless relays are assumed to
be off until they are turned on, and therefore will appear red (off)
when added. If a wireless relay is turned off or on outside Mycodo (by a
remote, for instance), Mycodo will not be able to determine the state of
the relay and will indicate whichever state the relay was last. This is,
if Mycodo turns the wireless relay on, and a remote is used to turn the
relay off, Mycodo will still assume the relay is on.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  BCM Pin               This is the GPIO that will be the signal to the
                        relay, using BCM numbering.

  On Trigger            This is the state of the GPIO to signal the
                        relay to turn the device on. HIGH will send a
                        3.3-volt signal and LOW will send a 0-volt
                        signal. If you relay completes the circuit (and
                        the device powers on) when a 3.3-volt signal is
                        sent, then set this to HIGH. If the device
                        powers when a 0-volt signal is sent, set this
                        to LOW.

  WiringPi Pin          This is the GPIO that will be the signal to the
                        relay, using WireingPi numbering.

  Protocol              This is the protocol to use to transmit via
                        433MHz. Default is 1, but if this doesn’t work,
                        increment the number.

  Pulse Length          This is the pulse length to transmit via
                        433MHz. Default is 189 ms.

  Bit Length            This is the bit length to transmit via 433MHz.
                        Default is 24-bit.

  On Command            This is the command used to turn the relay on.
                        For wireless relays, this is the numerical
                        command to be transmitted, and for command
                        relays this is the command to be executed.

  Off Command           This is the command used to turn the relay off.
                        For wireless relays, this is the numerical
                        command to be transmitted, and for command
                        relays this is the command to be executed.

  Current Draw (amps)   The is the amount of current the device powered
                        by the relay draws. Note: this value should be
                        calculated based on the voltage set in the
                        Relay Usage Settings.

  Start State           This specifies whether the relay should be ON
                        or OFF when mycodo initially starts. Wireless
                        relays have an additional option ‘Neither’
                        which will not issue an on or off command when
                        Mycodo starts or stops.

  Seconds to turn On    This is a way to turn a relay on for a specific
                        duration of time. This can be useful for
                        testing the relays and powered devices or the
                        measured effects a device may have on an
                        environmental condition.
  ---------------------------------------------------------------------


PIDs

A proportional-derivative-integral (PID) controller is a control loop
feedback mechanism used throughout industry for controlling systems. It
efficiently brings a measurable condition, such as the temperature, to a
desired state and maintains it there with little overshoot and
oscillation. A well-tuned PID controller will raise to the setpoint
quickly, have minimal overshoot, and maintain the setpoint with little
oscillation.

PID settings may be changed while the PID is activated and the new
settings will take effect immediately. If settings are changed while the
controller is paused, the values will be used once the controller
resumes operation.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Activate/Deactivate   Turn a particular PID controller on or off.

  Pause                 When paused, the PID will not turn on the
                        associated relays, and settings can be changed
                        without losing current PID output values.

  Hold                  When held, the PID will turn on the associated
                        relays, and settings can be changed without
                        losing current PID output values.

  Resume                Resume a PID controller from being held or
                        paused.

  Setpoint              This is the specific point you would like the
                        environment to be regaulted at. For example, if
                        you would like the humidity regulated to 60%,
                        enter 60.

  Direction             This is the direction that you wish to
                        regulate. For example, if you only require the
                        temperature to be raised, set this to “Up,” but
                        if you require regulation up and down, set this
                        to “Both.”

  Period                This is the duration between when the PID relay
                        turns off amd when the sensor takes another
                        measurement, the PID is updated, and the relay
                        is turned on again for another duration.

  Max Age               The time (in seconds) that the sensor
                        measurement age is required to be less than. If
                        the measurement is not younger than this age,
                        the measurement is thrown out and the PID will
                        not actuate the relay. This is a safety measure
                        to ensure the PID is only using recent
                        measurements.

  Raise Relay           This is the relay that will cause the
                        particular environmental condition to rise. In
                        the case of raising the temperature, this may
                        be a heating pad or coil.

  Min Duration (raise)  This is the minimum that the PID output must be
                        before the Up Relay turns on. If the PID output
                        exceeds this minimum, the Up Relay will turn on
                        for the PID output number of seconds.

  Max Duration (raise)  This is the maximum duration the Up Relay is
                        allowed to turn on for. If the PID output
                        exceeds this number, the Up Relay will turn on
                        for no greater than this duration of time.

  Lower Relay           This is the relay that will cause the
                        particular environmental condition to lower. In
                        the case of lowering the CO2, this may be an
                        exhaust fan.

  Min Duration (lower)  This is the minimum that the PID output must be
                        before the Down Relay turns on. If the PID
                        output exceeds this minimum, the Down Relay
                        will turn on for the PID output number of
                        seconds.

  Max Duration (lower)  This is the maximum duration the Down Relay is
                        allowed to turn on for. if the PID output
                        exceeds this number, the Down Relay will turn
                        on for no greater than this duration of time.

  KP                    Proportional coefficient (non-negative).
                        Accounts for present values of the error. For
                        example, if the error is large and positive,
                        the control output will also be large and
                        positive.

  KI                    Integral coefficient (non-negative). Accounts
                        for past values of the error. For example, if
                        the current output is not sufficiently strong,
                        the integral of the error will accumulate over
                        time, and the controller will respond by
                        applying a stronger action.

  KD                    Derivative coefficient (non-negative). Accounts
                        for predicted future values of the error, based
                        on its current rate of change.

  Integrator Min        The minimum allowed integrator value, for
                        calculating Ki_total: (Ki_total = Ki *
                        integrator; and PID output = Kp_total +
                        Ki_total + Kd_total)

  Integrator Max        The maximum allowed integrator value, for
                        calculating Ki_total: (Ki_total = Ki *
                        integrator; and PID output = Kp_total +
                        Ki_total + Kd_total)
  ---------------------------------------------------------------------


Timers

Timers enable a relay to be manipulated after specific durations of time
or at a specific times of the day. For _Duration Timers_, both the on
duration and the off duration can be defined and the timer will be
turned on and off for those durations until deactivated. For _Daily
Timers_, the start hour:minute can be set to turn a specific relay on or
off at the specific time of day.


LCDs

Data may be output to a liquid crystal display (LCD) for easy viewing.
There are only a few number fo LCDs that are supported. Only 16x2 and
20x4 character LCD displays with I2C backpacks are supported. Please see
the README for specific information regarding compatibility.

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Reset Flashing        If the LCD is flashing to alert you because it
                        was instructed to do so by a triggered
                        Conditional Statement, use this button to stop
                        the flashing.

  Type                  Select either a 16x2 or 20x4 character LCD
                        display.

  I2C Address           Select the I2C to communicate with the LCD.

  Multiplexer I2C       If the LCD is connected to a multiplexer,
  Address               select the multiplexer I2C address.

  Multiplexer Channel   If the LCD is connected to a multiplexer,
                        select the multiplexer channel the LCD is
                        connected to.

  Period                This is the period of time (in seconds) between
                        redrawing the LCD with new data.

  Display Line #        Select which measurement to display on each
                        line of the LCD.
  ---------------------------------------------------------------------



CONTROLLER FUNCTIONS


Conditional Statements

A conditional statement is a way to perform certain actions based on
whether a condition is true. Conditional statements can be created for
both relays and sensors. Possible conditional statements include:

-   If Relay #1 turns ON, turn Relay #3 ON
-   If Relay #1 turns ON, turn Relay #4 ON for 40 seconds and notify
    critical-issue@domain.com
-   If Relay #4 turns ON for 21 seconds, turn Relay #5 ON for 50 seconds
-   If Relay #4 turns ON for 20 seconds, turn Relay #1 OFF
-   If Humidity is Greater Than 80%, turn Relay #4 ON for 40 seconds
-   If Humidity if Less Than 50%, turn Relay #1 ON for 21 seconds,
    execute ‘/usr/local/bin/myscript.sh’, and notify email@domain.com
-   If Temperature if Greater Than 35 C, deactivate PID #1

Before activating any conditional statements or PID controllers, it’s
advised to thoroughly explore all possible scenarios and plan a
configuration that eliminates conflicts. Then, trial run your
configuration before connecting devices to the relays. Some devices or
relays may respond atypically or fail when switched on and off in rapid
succession. Therefore, avoid creating an infinite loop with conditional
statements.

Conditional Statement Actions

  ---------------------------------------------------------------------
  Setting               Description
  --------------------- -----------------------------------------------
  Relay                 Turn a relay on, off, or on for a duration of
                        time.

  Command               Execute a command in the linux shell (as user
                        mycodo).

  Activate PID          Activate a particular PID controller.

  Deactivate PID        Deactivate a particular PID controller.

  Email                 Send an email containing information about the
                        current condition that triggered the
                        conditional to send the email.

  Flash LCD             Have an LCD screen begin flashing in order to
                        alert.

  Photo                 Capture a photo with the selected camera.

  Email Photo           Capture a photo and email it as an attachment
                        to the an email address.

  Video                 Capture a video of a set duration with the
                        selected camera.

  Email Video           Capture a video and email it as an attachment
                        to the an email address.
  ---------------------------------------------------------------------


Methods

Methods allow different types of setpoint tracking in PID controllers.
Normally, a PID controller will regulate an environmental condition to a
specific setpoint. If you would like the setpoint to change over time,
this is called setpoint tracking. Setpoint tracking is useful for
applications such as reflow ovens, thermal cyclers (DNA replication),
mimicking natural daily cycles, and more.

Universal Options

These options are shared with several method types.

  Setting           Description
  ----------------- -----------------------------------------------------
  Start Time/Date   This is the start time of a range of time.
  End Time/Date     This is the end time of a range of time.
  Start Setpoint    This is the start setpoint of a range of setpoints.
  End Setpoint      This is the end setpoint of a range of setpoints.

Specific Method Options

Time/Date Method

A time/date method allows a specific time/date span to dictate the
setpoint. This is useful for long-running methods, that may take place
over the period of days, weeks, or months.

Duration Method

A duration method allows a specific durations of time to dictate the
setpoint. This is useful for when short periods of time are required in
a method, such as those that take place over the course of a few minutes
or hours. Each duration will stack on the previous duration, meaning a
newly-added start setpoint will begin from the previous entry’s end
setpoint.

Daily (Time-Based) Method

The daily time-based method is similar to the time/date method, however
it will repeat every day. Therefore, it is essential that only the span
of one day be set in this method. Begin with the start time at 00:00:00
and end at 23:59:59 (or 00:00:00, which would be 24 hours from the
start). The start time must be equal or greater than the previous end
time.

Daily (Sine Wave) Method

The daily sine wave method defines the setpoint over the day based on a
sinusoidal wave. The sine wave is defined by y = [A * sin(B * x + C)] +
D, where A is amplitude, B is frequency, C is the angle shift, and D is
the y-axis shift. This method will repeat daily.

Daily (Bezier Curve) Method

A daily Bezier curve method define the setpoint over the day based on a
cubic Bezier curve. If unfamiliar with a Bezier curve, it is recommended
you use the graphical Bezier curve generator and use the 8 variables it
creates for 4 points (each a set of x and y). The x-axis start (x3) and
end (x0) will be automatically stretched or skewed to fit within a
24-hour period and this method will repeat daily.


PID Tuning

PID Control Theory

The PID controller is the most common regulatory controller found in
industrial settings, for it“s ability to handle both simple and complex
regulation. The PID controller has three paths, the proportional,
integral, and derivative.

The Proportional takes the error and multiplies it by the constant Kp,
to yield an output value. When the error is large, there will be a large
proportional output.

The Integral takes the error and multiplies it by Ki, then integrates it
(Ki · 1/s). As the error changes over time, the integral will
continually sum it and multiply it by the constant Ki. The integral is
used to remove perpetual error in the control system. If using Kp alone
produces an output that produces a perpetual error (i.e. if the sensor
measurement never reaches the Set Point), the integral will increase the
output until the error decreases and the Set Point is reached.

The Derivative multiplies the error by Kd, then differentiates it (Kd ·
s). When the error rate changes over time, the output signal will
change. The faster the change in error, the larger the derivative path
becomes, decreasing the output rate of change. This has the effect of
dampening overshoot and undershoot (oscillation) of the Set Point.

------------------------------------------------------------------------

Using temperature as an example, the Process Variable (PV) is the
measured temperature, the Setpoint (SP) is the desired temperature, and
the Error (e) is the distance between the measured temperature and the
desired temperature (indicating if the actual temperature is too hot or
too cold and to what degree). The error is manipulated by each of the
three PID components, producing an output, called the Manipulated
Variable (MV) or Control Variable (CV). To allow control of how much
each path contributes to the output value, each path is multiplied by a
gain (represented by _KP_, _KI_, and _KD_). By adjusting the gains, the
sensitivity of the system to each path is affected. When all three paths
are summed, the PID output is produced. If a gain is set to 0, that path
does not contribute to the output and that path is essentially turned
off.

The output can be used a number of ways, however this controller was
designed to use the output to affect the measured value (PV). This
feedback loop, with a _properly tuned_ PID controller, can achieve a set
point in a short period of time, maintain regulation with little
oscillation, and respond quickly to disturbance.

Therefor, if one would be regulating temperature, the sensor would be a
temperature sensor and the feedback device(s) would be able to heat and
cool. If the temperature is lower than the Set Point, the output value
would be positive and a heater would activate. The temperature would
rise toward the desired temperature, causing the error to decrease and a
lower output to be produced. This feedback loop would continue until the
error reaches 0 (at which point the output would be 0). If the
temperature continues to rise past the Set Point (this is may be
acceptable, depending on the degree), the PID would produce a negative
output, which could be used by the cooling device to bring the
temperature back down, to reduce the error. If the temperature would
normally lower without the aid of a cooling device, then the system can
be simplified by omitting a cooler and allowing it to lower on its own.

Implementing a controller that effectively utilizes _KP_, _KI_, and _KD_
can be challenging. Furthermore, it is often unnecessary. For instance,
the _KI_ and _KD_ can be set to 0, effectively turning them off and
producing the very popular and simple P controller. Also popular is the
PI controller. It is recommended to start with only _KP_ activated, then
experiment with _KP_ and _KI_, before finally using all three. Because
systems will vary (e.g. airspace volume, degree of insulation, and the
degree of impact from the connected device, etc.), each path will need
to be adjusted through experimentation to produce an effective output.

Quick Setup Examples

These example setups are meant to illustrate how to configure regulation
in particular directions, and not to achieve ideal values to configure
your _KP_, _KI_, and _KD_ gains. There are a number of online resources
that discuss techniques and methods that have been developed to
determine ideal PID values (such as here, here, here, here, and here)
and since there are no universal values that will work for every system,
it is recommended to conduct your own research to understand the
variables and essential to conduct your own experiments to effectively
implement them.

Provided merely as an example of the variance of PID values, one of my
setups had temperature PID values (up regulation) of _KP_ = 30, _KI_ =
1.0, and _KD_ = 0.5, and humidity PID values (up regulation) of _KP_ =
1.0, _KI_ = 0.2, and _KD_ = 0.5. Furthermore, these values may not have
been optimal but they worked well for the conditions of my environmental
chamber.

Exact Temperature Regulation

This will set up the system to raise and lower the temperature to a
certain level with two regulatory devices (one that heats and one that
cools).

Add a sensor, then save the proper device and pin/address for each
sensor and activate the sensor.

Add two relays, then save each GPIO and On Trigger state.

Add a PID, then select the newly-created sensor. Change _Setpoint_ to
the desired temperature, _Regulate Direction_ to “Both”. Set _Raise
Relay_ to the relay attached to the heating device and the _Lower Relay_
to the relay attached to the cooling device.

Set _KP_ = 1, _KI_ = 0, and _KD_ = 0, then activate the PID.

If the temperature is lower than the Set Point, the heater should
activate at some interval determined by the PID controller until the
temperature rises to the set point. If the temperature goes higher than
the Set Point (or Set Point + Buffer), the cooling device will activate
until the temperature returns to the set point. If the temperature is
not reaching the Set Point after a reasonable amount of time, increase
the _KP_ value and see how that affects the system. Experiment with
different configurations involving only _Read Interval_ and _KP_ to
achieve a good regulation. Avoid changing the _KI_ and _KD_ from 0 until
a working regulation is achieved with _KP_ alone.

View graphs in the 6 to 12 hour time span to identify how well the
temperature is regulated to the Setpoint. What is meant by
well-regulated will vary, depending on your specific application and
tolerances. Most applications of a PID controller would like to see the
proper temperature attained within a reasonable amount of time and with
little oscillation around the Setpoint.

Once regulation is achieved, experiment by reducing _KP_ slightly (~25%)
and increasing _KI_ by a low amount to start, such as 0.1 (or lower,
0.01), then start the PID and observe how well the controller regulates.
Slowly increase _KI_ until regulation becomes both quick and with little
oscillation. At this point, you should be fairly familiar with
experimenting with the system and the _KD_ value can be experimented
with once both _KP_ and _KI_ have been tuned.

High Temperature Regulation

Often the system can be simplified if two-way regulation is not needed.
For instance, if cooling is unnecessary, this can be removed from the
system and only up-regulation can be used.

Use the same configuration as the Exact Temperature Regulation example,
except change _Regulate Direction_ to “Raise” and do not touch the “Down
Relay” section.



MISCELLANEOUS


Graphs

There are two different types of graphs, Live and Asynchronous.

Live Graphs

A graphical data display that is useful for viewing data sets spanning
relatively short periods of time (hours/days/weeks). Select a time frame
to view data and continually updating data from new sensor measurements.
Multiple graphs can be created on one page that enables a dashboard to
be created of graphed sensor data. Each graphs may have one or more
sensor measurement, relay duration, or PID setpoint rendered onto it.
Several live graph options exist, such as the time period (x-axis) and
line colors, as well as navigation and data/image export options. To
edit graph options, select the plus sign on the top-right of a graph.

Asynchronous Graphs

A graphical data display that is useful for viewing data sets spanning
relatively long periods of time (weeks/months/years), which could be
very data- and processor-intensive to view as a Live Graph. Select a
time frame and data will be loaded from that time span, if it exists.
The first view will be of the entire selected data set. For every
view/zoom, 700 data points will be loaded. If there are more than 700
data points recorded for the time span selected, 700 points will be
created from an averaging of the points in that time span. This enables
much less data to be used to navigate a large data set. For instance, 4
months of data may be 10 megabytes if all of it were downloaded.
However, when viewing a 4 month span, it’s not possible to see every
data point of that 10 megabytes, and aggregating of points is
inevitable. With asynchronous loading of data, you only download what
you see. So, instead of downloading 10 megabytes every graph load, only
~50kb will be downloaded until a new zoom level is selected, at which
time only another ~50kb is downloaded.

Note: Live Graphs require measurements to be acquired, therefore at
least one sensor needs to be added and activated in order to display
live data.


Camera

Once a cameras has been set up (in the Camera Settings), it may be used
to capture still images, create time-lapses, and stream video (Pi camera
only). Cameras may also be used with Conditional Statements to trigger a
camera image or video capture (as well as the ability to email the
image/video with a notification).


Relay Usage

Relay usage statistics are calculated for each relay, based on how long
the relay has been powered, the current draw of the device connected to
the relay, and other Relay Usage Settings.


System Backup

A backup is made to /var/Mycodo-backups when the system is upgraded
through the web interface or the upgrade script.


System Restore

If you need to restore a backup, do the following, changing the
appropriate directory names with these commands, changing ‘user’ to your
user name:

    sudo mv /home/user/Mycodo /home/user/Mycodo_old
    sudo cp -a /var/Mycodo-backups/Mycodo-TIME-COMMIT /home/user/Mycodo
    sudo /bin/bash ~/Mycodo/mycodo/scripts/upgrade_post.sh



TROUBLESHOOTING


Daemon Not Running

-   Check the Logs: From the [Gear Icon] -> Mycodo Logs page, check the
    Daemon Log for any errors. If the issue began after an upgrade, also
    check the Upgrade Log for indications of an issue.
-   Determine if the Daemon is Running: Execute
    ps aux | grep '/var/www/mycodo/env/bin/python /var/www/mycodo/mycodo/mycodo_daemon.py'
    in a terminal and look for an entry to be returned. If nothing is
    returned, the daemon is not running.
-   Daemon Lock File: If the daemon is not running, make sure the daemon
    lock file is deleted at /var/lock/mycodo.pid. The daemon cannot
    start if the lock file is present.
-   If a solution could not be found after investigating the above
    suggestions, submit a New Mycodo Issue on github.


More

Check out the Diagnosing Mycodo Issues Wiki Page on github for more
information about diagnosing issues.



SENSOR AND DEVICE SETUP


Certain sensors will require extra steps to be taken in order to set up
the interface for communication. This includes I2C, one-wire, and UART.


Sensor Interfaces

Sensors are categorized below by their communication interface.

1-Wire

The 1-wire interface should be configured with these instructions.

  DS18B20: Temperature link (Also works with: DS18S20, DS1822, DS28EA00,
  DS1825/MAX31850K)

GPIO

  DHT11, DHT22/AM2302: Relative humidity and temperature link

  SHT1x/SHT7x, SHT2x: Relative humidity and temperature link

UART

  Atlas Scientific pH: pH link

  Atlas Scientific PT-1000: Temperature link

  K30: Carbon dioxide (CO2) in ppmv link

  MH-Z19: Carbon dioxide (CO2) in ppmv link

This documentation provides specific installation procedures for
configuring UART with the Raspberry Pi version 1 or 2.

The K30 may be tested by executing
~/Mycodo/mycodo/tests/manual_tests/test_uart_K30.py

For Atlas Scientific sensors, this guide may be used, as well as the
above K-30 guide, to set up UART on the Raspberry Pi 1 and 2. However,
for Pi 3s, use the procedure below.

Because the UART is handled differently by the Raspberry Pi 3, from of
the addition of bluetooth, there are a different set of instructions. If
installing Mycodo on a Raspberry Pi 3, you only need to perform these
steps to configure UART:

Run raspi-config

sudo raspi-config

Go to Advanced Options -> Serial and disable. Then edit /boot/config.txt

sudo vi /boot/config.txt

Find the line “enable_uart=0” and change it to “enable_uart=1”, then
reboot.

I2C

The I2C interface should be enabled with raspi-config.

  AM2315: Relative humidity, temperature link

  Atlas Scientific pH: pH link

  Atlas Scientific PT-1000: Temperature link

  BH1750: Light link

  BME280: Barometric pressure, humidity, temperature link

  BMP085, BMP180: Barometric pressure, temperature link

  HTU21D: Relative humidity and temperature link

  TMP006, TMP007: Contactless temperature link

  TSL2561: Light link

  Chirp: link Moisture, light, and temperature


Edge Detection

The detection of a changing signal, for instance a simple switch
completing a circuit, requires the use of edge detection. By detecting a
rising edge (LOW to HIGH), a falling edge (HIGH to LOW), or both,
actions or events can be triggered. The GPIO chosen to detect the signal
should be equipped with an appropriate resistor that either pulls the
GPIO up [to 5-volts] or down [to ground]. The option to enable the
internal pull-up or pull-down resistors is not available for safety
reasons. Use your own resistor to pull the GPIO high or low.

Examples of devices that can be used with edge detection: simple
switches and buttons, PIR motion sensors, reed switches, hall effect
sensors, float switches, and more.


Device Setup

I2C Multiplexers

All devices that connected to the Raspberry Pi by the I2C bus need to
have a unique address in order to communicate. Some sensors may have the
same address (such as the AM2315), which prevents more than one from
being connected at the same time. Others may provide the ability to
change the address, however the address range may be limited, which
limits by how many you can use at the same time. I2C multiplexers are
extremely clever and useful in these scenarios because they allow
multiple sensors with the same I2C address to be connected.

  TCA9548A: I2C Multiplexer link (I2C): Has 8 selectable addresses, so 8
  multiplexers can be connected to one Raspberry Pi. Each multiplexer
  has 8 channels, allowing up to 8 devices/sensors with the same address
  to be connected to each multiplexer. 8 multiplexers x 8 channels = 64
  devices/sensors with the same I2C address.

  TCA9545A: I2C Bus Multiplexer link (I2C): This board works a little
  differently than the TCA9548A, above. This board actually creates 4
  new I2C busses, each with their own selectable voltage, either 3.3 or
  5.0 volts. Instructions to enable the Device Tree Overlay are at
  https://github.com/camrex/i2c-mux-pca9545a. Nothing else needs to be
  done in Mycodo after that except to select the correct I2C bus when
  configuring a sensor.

Analog to Digital Converters

An analog to digital converter (ADC) allows the use of any analog sensor
that outputs a variable voltage. A voltage divider may be necessary to
attain your desired range.

  ADS1x15 link ±4.096 (I2C)

  MCP342x link ±2.048 (I2C)



DEVICE SPECIFIC INFORMATION


Temperature Sensors

Raspberry Pi

The Raspberry Pi has an integrated temperature sensor on the BCM2835 SoC
that measure the temperature of the CPU/GPU. This is the easiest sensor
to set up in Mycodo, as it is immediately available to be used.

Atlas Scientific PT-1000

The PT1000 temperature probe is a resistance type thermometer. Where PT
stands for platinum and 1000 is the measured resistance of the probe at
0°C in ohms (1k at 0°C).

Specifications

-   UART or I2C
-   Accuracy ±(0.15 + (0.002*t))
-   Probe type: Class A Platinum, RTD (resistance temperature detector)
-   Cable length: 81cm (32“)
-   Cable material: Silicone rubber
-   30mm sensing area (304 SS)
-   6mm Diameter
-   BNC Connector
-   Reaction Time: 90% value in 13 seconds
-   Probe output: analog
-   Full temperature sensing range: -200°C to 850°C
-   Cable max temp 125°C
-   Cable min temp -55°C

DS18B20

The DS18B20 is a 1-Wire digital temperature sensor from Maxim IC. Each
sensor has a unique 64-Bit Serial number, allowing for a huge number of
sensors to be used on one data bus (GPIO 4).

Specifications

-   Usable temperature range: -55 to 125°C (-67°F to +257°F)
-   9 to 12 bit selectable resolution
-   Uses 1-Wire interface- requires only one digital pin for
    communication
-   Unique 64 bit ID burned into chip
-   Multiple sensors can share one pin
-   ±0.5°C Accuracy from -10°C to +85°C
-   Temperature-limit alarm system
-   Query time is less than 750ms
-   Usable with 3.0V to 5.5V power/data

TMP006, TMP007

The TMP006 Breakout can measure the temperature of an object without
making contact with it. By using a thermopile to detect and absorb the
infrared energy an object is emitting, the TMP006 Breakout can determine
how hot or cold the object is.

Specifications

-   Usable temperature range: -40°C to 125°C
-   Optimal operating voltage of 3.3V to 5V (tolerant up to 7V max)


Temperature, Humidity Sensors

AM2315

Specifications

-   0-100% humidity readings with 1% (10-90% RH) and 3% (0-10% RH and
    90-100% RH) accuracy
-   -20 to 80°C temperature readings ±0.1°C typical accuracy
-   3.5 to 5.5V power and I/O
-   10 mA max current use during conversion (while requesting data)
-   No more than 0.5 Hz sampling rate (once every 2 seconds)

DHT11

Specifications

-   3 to 5V power and I/O
-   2.5mA max current use during conversion (while requesting data)
-   20-80% humidity readings with 5% accuracy
-   0-50°C temperature readings ±2°C accuracy
-   No more than 1 Hz sampling rate (once every second)

DHT22, AM2302

Compared to the DHT11, this sensor is more precise, more accurate and
works in a bigger range of temperature/humidity, but its larger and more
expensive. The wiring is the same as the DHT11.

Specifications

-   0-100% humidity readings with 2% (10-90% RH) and 5% (0-10% RH and
    90-100% RH) accuracy
-   -40 to 80°C temperature readings ±0.5°C accuracy
-   3 to 5V power and I/O
-   2.5mA max current use during conversion (while requesting data)
-   No more than 0.5 Hz sampling rate (once every 2 seconds)

HTU21D

Specifications

-   0-100% humidity readings with 2% (20-80% RH) and 2%-5% (0-20% RH and
    80-100% RH) accuracy
-   Optimum accuracy measurements within 5 to 95% RH
-   -30 to 90°C temperature readings ±1°C typical accuracy

SHT1x

(SHT10, SHT11, SHT15)

Specifications

-   0-100% humidity readings with 2%-5% (10-90% RH) and 2%-7.5% (0-10%
    RH and 90-100% RH) accuracy
-   -40 to 125°C temperature readings ±0.5°C, ±0.4°C, and ±0.3°C typical
    accuracy (respectively)
-   2.4 to 5.5V power and I/O
-   No more than 0.125 Hz sampling rate (once every 8 seconds)

SHT7x

(SHT71, SHT75)

Specifications

-   0-100% humidity readings with 2%-3% (10-90% RH) and 2%-5% (0-10% RH
    and 90-100% RH) accuracy
-   -40 to 125°C temperature readings ±0.4°C and ±0.3°C typical
    accuracy (respectively)
-   2.4 to 5.5V power and I/O
-   No more than 0.125 Hz sampling rate (once every 8 seconds)


CO2 Sensors

K-30

[] 

Be very careful when connecting the K-30, as there is no reverse-voltage
protection and improper connections could destroy your sensor.

Wiring instructions for the Raspberry Pi can be found here.

Specifications

-   0 – 10,000 ppmv (0 - 5,000 ppmv within specifications)
-   Repeatability: ±20 ppm ±1% of measured value within specifications
-   Accuracy: ±30 ppm ±3% of measured value within specifications
-   Non-dispersive infrared (NDIR) technology
-   Sensor life expectancy: > 15 years
-   Self-diagnostics: complete function check of the sensor module
-   Warm-up time: < 1 min. (@ full specs < 15 min)
-   0.5 Hz sampling rate (once every 2 seconds)

MH-Z19

Specifications

-   0 – 5,000 ppmv
-   Accuracy: ±50 ppm ±5% of measured value within specifications
-   Non-dispersive infrared (NDIR) technology
-   Sensor life expectancy: > 5 years
-   Warm-up time: 3 min.
-   0.2 Hz sampling rate (once every 5 seconds)


Moisture Sensors

Chirp

The Chirp sensor measures moisture, light, and temperature.

Specifications

-   Vin: 3 to 5V
-   I2C 7-bit address 0x77


pH Sensors

Atlas Scientific pH

The Atlas Scientific pH sensor measures the pH of a liquid.

Specifications

-   UART or I2C
-   Probe Max Pressure: 690 kPa (100PSI)
-   Probe Max Depth 60 M (197 ft)
-   Probe Weight: 49 grams
-   Probe can be fully submerged in fresh or salt water indefinitely


Pressure Sensors

BME280

The BME280 is the upgrade to the BMP085/BMP180/BMP183. It has a low
altitude noise of 0.25m and the same fast conversion time. It has the
same specifications, but can use either I2C or SPI.

Specifications

-   300-1100 hPa (9000m to -500m above sea level)
-   -40 to +85°C operational range
-   ±3% humidity accuracy tollerance
-   ±1% humidity hysteresis
-   ±1 hPa pressure accuracy
-   ±2°C temperature accuracy
-   Vin: 3 to 5V
-   Logic: 3 to 5V compliant
-   I2C 7-bit address 0x76 or 0x77

BMP085, BMP180

The BMP180 replaces the BMP085. It is completely identical to the BMP085
in terms of firmware/software/interfacing.

Specifications

-   300-1100 hPa (9000m to -500m above sea level)
-   Up to 0.03hPa / 0.25m resolution
-   -40 to +85°C operational range
-   ±2°C temperature accuracy
-   Vin: 3 to 5V
-   Logic: 3 to 5V compliant
-   I2C 7-bit address 0x77


Luminosity Sensors

BH1750

The BH1750 is an I2C luminosity sensor that provides a digital value in
lux (lx) over a range of 1 - 65535 lx.

TSL2561

The TSL2561 SparkFun Luminosity Sensor Breakout is a sophisticated light
sensor which has a flat response across most of the visible spectrum.
Unlike simpler sensors, the TSL2561 measures both infrared and visible
light to better approximate the response of the human eye. And because
the TSL2561 is an integrating sensor (it soaks up light for a
predetermined amount of time), it is capable of measuring both small and
large amounts of light by changing the integration time.

Specifications

-   Light range: 0.1 - 40k+ lux
-   Vin: 3V and a low supply
-   Max current: 0.6mA.


Analog to Digital Converters

ADS1x15

(ADS1015, ADS1115)

Specifications

-   Interface: I2C
-   I2C 7-bit addresses 0x48 - 0x4B
-   Input channels: 2 (differential), 4 (single-ended)
-   Power: 2.0V to 5.5V
-   Sample Rate: 1015: 128SPS to 3.3kSPS, 1115: 8SPS to 860SPS
-   Resolution: 1015: 12-bit, 1115: 16-bit

MCP342x

(MCP3422, MCP3423, MCP3424, MCP3426, MCP3427, MCP3428)

Specifications

-   Interface: I2C
-   I2C 7-bit addresses 0x68 - 0x6F
-   MCP3422: 2 channel, 12, 14, 16, or 18 bit
-   MCP3423: 2 channel, 12, 14, 16, or 18 bit
-   MCP3424: 4 channel, 12, 14, 16, or 18 bit
-   MCP3426: 2 channel, 12, 14, or 16 bit
-   MCP3427: 2 channel, 12, 14, or 16 bit
-   MCP3428: 4 channel, 12, 14, or 16 bit


Diagrams

DHT11 Diagrams

[] 

[] 

DS18B20 Diagrams

[] 

[] 

[] 

Raspberry Pi and Relay Diagrams

Raspberry Pi, 4 relays, 4 outlets, 1 DS18B20 sensor.

[Schematic: Pi, 4 relays, 4 outlets, and 1 DS18B20 sensor] 

Raspberry Pi, 8 relays, 8 outlets.

[Schematic: Pi, 8 relays, and 8 outlets]