[SystemParameters]
HMS Software Version=2.4.1
Working Directory=C:\PROGRA~1\HALLME~1
[Measurement State Machine]
Use instruments=True
System Model=0
Wiring=0
Reconfirm Ammeter Removal=True
ElectroMeter=0
Control ElectroMeter=False
NumberOfSamples=2
2 Sample Labeling=1
VoltMeter=1
CurrentMeter=1
Current Source=0
AC Hall=False
AC Hall type=0
Contact Blasting=False
[Keithley 7001]
Resting State=0
[Keithley 6485]
Reading Rate=0
Median Filter=False
Median Filter Rank=1
Digital Filter=False
Digital Filter Type=0
Digital Filter Count=10
Advanced Filter=False
Noise Window=0
[Keithley 220]
Compliance Voltage=100
[Keithley 2000]
Reading Rate=1
Digital Filter=True
Digital Filter Type=0
Digital Filter Count=10
[Keithley 2182]
Line Synchronization=True
Reading_Rate=0
Analog Filter=False
Digital Filter=True
Digital_Filter_Type=0
Digital Filter Window=1
Digital Filter Count=10
[Keithley 182]
Integration Time=0
Analog Filter=False
Digital Filter=2
[Keithley 2700]
Line Synchronization=True
Reading Rate=1
Resting State=0
Digital Filter=True
Digital Filter Type=0
Digital Filter Window=1
Digital Filter Count=10
[Keithley 2400]
Compliance Voltage=20
[Field Controller]
Gaussmeter=0
Use LS475 Built-in PI Controller=True
Setpoint Ramping=False
Ramp Rate=500
Field P=1
Field I=25
Field D=0
Power Supply=0
Settle_Band=0.0002
Settle_Time=1
LS450 Display Unit=0
Shutdown Field at end of measurement=False
Log Field data=False
Enable Settle Time Out=False
Settle Time Out=5
Time to Setpoint for Demo=5
[Temperature Controller]
Temperature=True
Sample Module=2
Monitor Only=False
Sample Channel=1
As Loop 1 Input=True
Sample Sensor Type=1
Sample Sensor Curve Number=24
Sample Sensor Filter=True
Sample Sensor Filter Points=10
Sample Sensor Filter Window=1
Sample Sensor Thermal EMF Compensation=1
Sample Sensor Room Compensation=True
Sample Sensor ThermoCouple Range=0
Log Temperature data=False
Front panel displays=2
Front panel input channel 1=0
Front panel display item 1=0
Front panel input channel 2=1
Front panel display item 2=0
Front panel input channel 3=0
Front panel display item 3=0
Front panel input channel 4=0
Front panel display item 4=0
Front panel input channel 5=0
Front panel display item 5=0
Front panel input channel 6=0
Front panel display item 6=0
Front panel input channel 7=0
Front panel display item 7=0
Front panel input channel 8=0
Front panel display item 8=0
Front panel control display=3
Front panel large output=False
Front panel heater display=0
Shutdown Heater at the end of software=True
Number of Domains=8
[Temperature Controller - Loop 1]
Setp Unit=0
Control Filter=False
Heater Resistance=49
Setp Limit=350
Max Positive Slope=0
Max Negative Slope=0
Max Heater Current=2
Max Heater Range=5
Input channel=0
Sensor Type=0
Curve Number=1
Filter=True
Filter Points=10
Filter Window=1
Thermal_EMF Compensation=1
Room Compensation=True
ThermoCouple Range=1
[Temperature Controller - Loop 2]
Setp Unit=0
Control Filter=False
Setp Limit=350
Max Positive Slope=0
Max Negative Slope=0
[Temperature Domain 1]
Temperature Low=0
Temperature High=14
Direction=1
Loop 1 P=40
Loop 2 P=10
Loop 1 I=1
Loop 2 I=2
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=0.5
Settle Temperature Band=0.5
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 2]
Temperature Low=14
Temperature High=21
Direction=1
Loop 1 P=40
Loop 2 P=10
Loop 1 I=1
Loop 2 I=2
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=0.5
Settle Temperature Band=0.5
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 3]
Temperature Low=21
Temperature High=29
Direction=1
Loop 1 P=50
Loop 2 P=10
Loop 1 I=2
Loop 2 I=2
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=0.7
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 4]
Temperature Low=29
Temperature High=49
Direction=1
Loop 1 P=60
Loop 2 P=10
Loop 1 I=3
Loop 2 I=2
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=1
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 5]
Temperature Low=49
Temperature High=151
Direction=1
Loop 1 P=100
Loop 2 P=10
Loop 1 I=4
Loop 2 I=1.1
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=1
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 6]
Temperature Low=151
Temperature High=400
Direction=1
Loop 1 P=100
Loop 2 P=10
Loop 1 I=5
Loop 2 I=1.1
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=1
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 7]
Temperature Low=400
Temperature High=1000
Direction=1
Loop 1 P=0
Loop 2 P=0
Loop 1 I=0
Loop 2 I=0
Loop 1 D=0
Loop 2 D=0
Heater Range=0
Loop 2 Heater=0
Loop 1 Setpoint Offset=0
Ramp Rate=1
Settle Wait Time=0
Settle Temperature Drift=0.5
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Temperature Domain 8]
Temperature Low=0
Temperature High=1000
Direction=2
Loop 1 P=100
Loop 2 P=20
Loop 1 I=5
Loop 2 I=2
Loop 1 D=0
Loop 2 D=0
Heater Range=5
Loop 2 Heater=1
Loop 1 Setpoint Offset=0
Ramp Rate=2
Settle Wait Time=0
Settle Temperature Drift=0.5
Settle Temperature Band=1
Settle Time Out=True
Settle Time Out Period=100
Needle Valve During Ramp=0
Needle Valve After Ramp=0
Sample Space Evacuation Valve During Ramp=0
Sample Space Evacuation Valve After Ramp=0
[Platform System]
Superconducting Magnet=1
Superconducting Power Supply=0
Field Current Ratio=2000
Compliance Voltage=5
Voltage Drift=0.001
Maximum Current=45
Ramp Rate=0.05
Wait Time=40
Display Unit=0
Stepping Motor Controller=0
Stepping Motor Comm Port=0
Needle Valve Position=0
Use LS241=False
LS241 Comm Port=1
LS241 Sample Period=60
LS241 Display Unit=0
Power Booster=False
Stepper Motor=0
Use Needle Valve Stepper=True
Needle Valve Motor Steps per rev=480
Needle Valve Motor Max RPM=25
[Lake Shore 370]
LS370 Change Pause Time=6
LS370 Common Mode Reduction=False