PDS3_DATA_SET_ID               = VG1-S-CRS-4-SUMM-D1/D2-192SEC-V1.0           
DATA_SET_NAME                  = VG1 SAT CRS RESAMPLED SUMMARY D1 RATE        
                                      ELEC 192SEC V1.0                        
START_TIME                     = 1980-11-11T16:01:36.000                      
STOP_TIME                      = 1980-11-14T22:01:36.000                      
ORIGINAL_DATA_SET_RELEASE_DATE = 1996-07-01                                   
PRODUCER_FULL_NAME             = RICHARD S. SELESNICK                         
                                                                              
REFERENCE:                                                                    
                                                                              
Stone, E.C., R.E. Vogt, F.B. McDonald, B.J. Teegarden, J.H. Trainor,          
J.R. Jokipii, and W.R. Webber, Cosmic ray investigation for the Voyager       
missions; energetic particle studies in the outer heliosphere--and beyond,    
Space Sci. Rev., 12, No. 3, 355-376, Dec. 1977.                               
                                                                              
                                                                              
    DATA_SET_DESCRIPTION                                                      
                                                                              
    Data Set Overview                                                         
   ====================                                                       
This data set describes the counting rate data from detectors D1 and D2       
in the Cosmic Ray System (CRS) electron telescope (TET) on Voyager 1 during   
the Saturn encounter. The D1 detector nominally responds to electrons with    
kinetic energies above approximately 1 MeV, and the D2 detector, above        
approximately 2.5 MeV (see detector description for details).                 
                                                                              
Note that the instrument is saturated near the maximum of counting            
rate of approximately 50,000 counts/sec. When data are near saturation,       
the counting rates should be corrected for deadtime according to the formula  
in the DATA_SET_OR_INST_PARM_DESC:                                            
{corrected rate} = {uncorrected rate/(1+deadtime*{uncorrected rate}).         
                                                                              
    Parameters                                                                
    ===============                                                           
                                                                              
    SAMPLING_PARAMETER_RESOLUTION  = 192.0                                    
    MINIMUM_SAMPLING_PARAMETER     = N/A                                      
    MAXIMUM_SAMPLING_PARAMETER     = N/A                                      
    SAMPLING_PARAMETER_INTERVAL    = 192.0                                    
    MINIMUM_AVAILABLE_SAMPLING_INT = 192.0                                    
    SAMPLING_PARAMETER_UNIT        = SECOND                                   
    DATA_SET_PARAMETER_NAME        = D1/D2 RATE                               
    NOISE_LEVEL                    = 0.000                                    
    DATA_SET_PARAMETER_UNIT        = COUNTS/SECOND                            
                                                                              
                                                                              
    CONFIDENCE_LEVEL_NOTE =                                                   
    Confidence Level                                                          
    =================                                                         
Each data point represents a six-second accumulation, so that the             
statistical uncertainty is obtained according to Poisson statistics by        
taking the square root of one sixth of the counting rate.  However,           
larger uncertainties are associated with the conversion from counting         
rate to flux (see the DATA_SET_OR_INST_PARM_DESC).                            
                                                                              
    Data Coverage                                                             
    =============                                                             
    Filename Records Start                     Stop                           
    ----------------------------------------------------------------------    
    Volume ID: VG_1601                                                        
    D1D2.TAB  1310  1980-11-11T16:01:36.000Z  1980-11-14T22:01:36.000Z        
                                                                              
    Missing Data Flag                                                         
    ==================                                                        
    Any data column whose value is -9.999e+10 is a missing data value.        
                                                                              
