Checking connectivity ... 4 connected groups, 0 isolated buses
Elapsed time is 0.00 seconds.
================================================================================
                        Full       Island      Island      Island      Island   
                       System         1           2           3           4     
Number of:           ----------  ----------  ----------  ----------  ---------- 
  buses                   171         118          30          14           9   
  loads                   133          99          20          11           3   
    on                    133          99          20          11           3   
    off                     -           -           -           -           -   
    fixed                 133          99          20          11           3   
    dispatchable            -           -           -           -           -   
      on                    -           -           -           -           -   
      off                   -           -           -           -           -   
  generators               68          54           6           5           3   
    on                     68          54           6           5           3   
    off                     -           -           -           -           -   
  shunt elements           17          14           2           1           -   
  branches                256         186          41          20           9   
    on                    256         186          41          20           9   
    off                     -           -           -           -           -   
    ties (off)              -           -           -           -           -   

Load                
  active (MW)       
    dispatched           5005.2      4242.0       189.2       259.0       315.0 
      fixed              5005.2      4242.0       189.2       259.0       315.0 
      dispatchable          -           -           -           -           -   
    nominal              5005.2      4242.0       189.2       259.0       315.0 
      on                 5005.2      4242.0       189.2       259.0       315.0 
      off                   -           -           -           -           -   
      fixed              5005.2      4242.0       189.2       259.0       315.0 
      dispatchable          -           -           -           -           -   
        on                  -           -           -           -           -   
        off                 -           -           -           -           -   
  reactive (MVAr)   
    dispatched           1733.7      1438.0       107.2        73.5       115.0 
      fixed              1733.7      1438.0       107.2        73.5       115.0 
      dispatchable          -           -           -           -           -   
    nominal              1733.7      1438.0       107.2        73.5       115.0 
      on                 1733.7      1438.0       107.2        73.5       115.0 
      off                   -           -           -           -           -   
      fixed              1733.7      1438.0       107.2        73.5       115.0 
      dispatchable          -           -           -           -           -   
        on                  -           -           -           -           -   
        off                 -           -           -           -           -   

Generation          
  active (MW)       
    dispatched           5087.0      4377.4       189.2       272.4       248.0 
    max capacity        11893.6      9966.2       335.0       772.4       820.0 
      on                11893.6      9966.2       335.0       772.4       820.0 
      off                   -           -           -           -           -   
    min capacity           30.0         -           -           -          30.0 
      on                   30.0         -           -           -          30.0 
      off                   -           -           -           -           -   
  reactive (MVAr)   
    dispatched             78.5         -           -          78.5         -   
    max capacity        13230.9     11777.0       405.9       148.0       900.0 
      on                13230.9     11777.0       405.9       148.0       900.0 
      off                   -           -           -           -           -   
    min capacity        -8392.0     -7345.0       -95.0       -52.0      -900.0 
      on                -8392.0     -7345.0       -95.0       -52.0      -900.0 
      off                   -           -           -           -           -   

Shunt Injections    
    active (MW)             -           -           -           -           -   
    reactive (MVAr)       105.8        84.4         0.2        21.2         -   

Branch Losses       
    active (MW)             -           -           -           -           -   
    reactive (MVAr)         -           -           -           -           -   

DC line             
  export (MW)       
    dispatch                -           -           -           -           -   
    max capacity            -           -           -           -           -   
      on                    -           -           -           -           -   
      off                   -           -           -           -           -   
    min capacity            -           -           -           -           -   
      on                    -           -           -           -           -   
      off                   -           -           -           -           -   

Reference Buses     
  num of ref buses          4           1           1           1           1   
  ref bus numbers        1069        1069        2001        3001        4001   
                         2001                                                   
                         3001                                                   
                         4001                                                   