dot-get_H.RdH: sensible heat flux density (W / m^2)
.get_H(T_leaf, pars, unitless)
| T_leaf | Leaf temperature in Kelvin |
|---|---|
| pars | Concatenated parameters ( |
| unitless | Logical. Should function use parameters with |
Value in W / m\(^2\) of class units
$$H = P_\mathrm{a} c_p g_\mathrm{h} (T_\mathrm{leaf} - T_\mathrm{air})$$
| Symbol | R | Description | Units | Default |
| \(c_p\) | c_p | heat capacity of air | J / (g K) | 1.01 |
| \(g_\mathrm{h}\) | g_h | boundary layer conductance to heat | m / s | calculated |
| \(P_\mathrm{a}\) | P_a | density of dry air | g / m^3 | calculated |
| \(T_\mathrm{air}\) | T_air | air temperature | K | 298.15 |
| \(T_\mathrm{leaf}\) | T_leaf | leaf temperature | K | input |
library(tealeaves) cs <- make_constants() ep <- make_enviropar() lp <- make_leafpar() T_leaf <- set_units(298.15, K) tealeaves:::.get_H(T_leaf, c(cs, ep, lp), FALSE)#> 0 [J/m^2/s]