Convert conductance units

convert_conductance(.g, Temp = NULL, P = NULL)

Arguments

.g

Conductance in class units. Units must convertible to one of "m/s", "umol/m^2/s/Pa", or "mol/m^2/s"

Temp

A temperature value of class units

P

A pressure value of class units that is convertible to kPa

Value

A list of three values of clas units with units "m/s", "umol/m^2/s/Pa", and "mol/m^2/s".

Examples

g_sw <- set_units(10, "m/s") convert_conductance(g_sw, Temp = set_units(298.15, "K"), P = set_units(101.3246, "kPa"))
#> $`m/s` #> 10 [m/s] #> #> $`umol/m^2/s/Pa` #> 4033.956 [umol/m^2/Pa/s] #> #> $`mol/m^2/s` #> 408.739 [mol/m^2/s] #>
g_sw <- set_units(4, "umol/m^2/s/Pa") convert_conductance(g_sw, Temp = set_units(298.15, "K"), P = set_units(101.3246, "kPa"))
#> $`m/s` #> 0.009915825 [m/s] #> #> $`umol/m^2/s/Pa` #> 4 [umol/m^2/Pa/s] #> #> $`mol/m^2/s` #> 0.4052984 [mol/m^2/s] #>
g_sw <- set_units(0.4, "mol/m^2/s") convert_conductance(g_sw, Temp = set_units(298.15, "K"), P = set_units(101.3246, "kPa"))
#> $`m/s` #> 0.009786197 [m/s] #> #> $`umol/m^2/s/Pa` #> 3.947709 [umol/m^2/Pa/s] #> #> $`mol/m^2/s` #> 0.4 [mol/m^2/s] #>