! do relax_M_center to increase the mass back to 0.003

! inlist_rc2

&star_job

      read_extra_star_job_inlist1 = .true.
      extra_star_job_inlist1_name = '../inlist_test_suite'
      
      show_log_description_at_start = .false. 
      
      load_saved_model = .true.
      saved_model_name = 'rc1.mod'

      save_model_number = 21
      save_model_filename = 'rc2.mod'

      kappa_file_prefix = 'gs98'
      kappa_lowT_prefix = 'lowT_Freedman11'

      relax_M_center = .true. 
      new_mass = 0.003
      dlgm_per_step = 1d-3
      relax_M_center_dt = 3.1558149984d-1 ! secyer*1d-8

/ ! end of star_job namelist

&controls

      ! check for retries and backups as part of test_suite
      ! you can/should delete this for use outside of test_suite
         max_number_backups = 25
         max_number_retries = 15



      initial_mass =  0.003
      initial_z = 0.02d0
      
      max_model_number = 22
      max_years_for_timestep = 0.1

      which_atm_option = 'tau_100_tables'

      photostep = 50
      profile_interval = 50
      history_interval = 10
      terminal_cnt = 10
      write_header_frequency = 10
      ! FOR DEBUGGING

      !report_hydro_solver_progress = .true. ! set true to see info about newton iterations
      !report_ierr = .true. ! if true, produce terminal output when have some internal error
      !hydro_show_correction_info = .true.
      
      !max_years_for_timestep = 3.67628942044319d-05

      !report_why_dt_limits = .true.
      !report_all_dt_limits = .true.
      
      !show_mesh_changes = .true.
      !mesh_dump_call_number = 5189
      !okay_to_remesh = .false.
      
      !trace_evolve = .true.
            

      ! hydro debugging
      !hydro_check_everything = .true.
      !hydro_inspectB_flag = .true.
      
      !hydro_numerical_jacobian = .true.
      !hydro_save_numjac_plot_data = .true.
      !small_mtx_decsol = 'lapack'
      !large_mtx_decsol = 'lapack'
      !hydro_dump_call_number = 195

      !trace_newton_bcyclic_solve_input = .true. ! input is "B" j k iter B(j,k)
      !trace_newton_bcyclic_solve_output = .true. ! output is "X" j k iter X(j,k)
      
      !trace_newton_bcyclic_steplo = 1 ! 1st model number to trace
      !trace_newton_bcyclic_stephi = 1 ! last model number to trace
      
      !trace_newton_bcyclic_iterlo = 2 ! 1st newton iter to trace
      !trace_newton_bcyclic_iterhi = 2 ! last newton iter to trace
      
      !trace_newton_bcyclic_nzlo = 1 ! 1st cell to trace
      !trace_newton_bcyclic_nzhi = 10000 ! last cell to trace; if < 0, then use nz as nzhi
      
      !trace_newton_bcyclic_jlo = 1 ! 1st var to trace
      !trace_newton_bcyclic_jhi = 100 ! last var to trace; if < 0, then use nvar as jhi
      
      !trace_k = 0

/ ! end of controls namelist