PDS Validate Tool Report

Configuration:
   Version                       3.2.0
   Date                          2023-05-12T16:09:15Z

Parameters:
   Targets                       [file:/V:/stage/m2020/aawork/SUPERCAM/validation/troubleshooting/product/]
   Severity Level                WARNING
   Recurse Directories           true
   File Filters Used             [*.xml, *.XML]
   Data Content Validation       on
   Product Level Validation      on
   Max Errors                    100000
   Registered Contexts File      V:\stage\tools\pds4_validate\validate-3.2.0\bin\..\resources\registered_context_products.json



Product Level Validation Results

  FAIL: file:/V:/stage/m2020/aawork/SUPERCAM/validation/troubleshooting/product/scam_0072_0673327336_185_cp2_scam01072_scct_41_irsalign_____04p04.xml
      ERROR  [error.label.invalid_object_definition]   line 12: Invalid object definition for object #12.  The previously defined object ends at byte 146432. Offset defined in label: 141120
    Begin Content Validation: file:/V:/stage/m2020/aawork/SUPERCAM/validation/troubleshooting/product/scam_0072_0673327336_185_cp2_scam01072_scct_41_irsalign_____04p04.fits
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 181, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 182, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 184, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 184, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 184, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 184, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 185, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 187, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 187, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 187, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 187, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 188, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 190, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 190, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 190, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 190, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 191, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 193, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 193, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 193, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 193, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 194, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 196, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 196, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 196, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 196, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 197, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 199, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 199, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 199, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 199, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 200, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 202, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 202, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 202, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 202, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 203, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 205, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 205, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 205, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 205, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 206, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 206, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 207, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 207, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 208, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 208, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 208, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 208, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 209, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 211, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 211, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 211, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 211, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 212, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 214, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 214, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 214, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 214, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 215, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 217, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 217, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 217, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 217, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 218, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 220, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 220, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 220, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 220, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 221, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 223, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 223, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 223, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 223, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 224, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 226, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 226, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 226, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 226, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 227, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 229, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 229, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 229, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 229, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 230, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 232, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 232, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 232, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 232, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 233, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 235, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 235, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 235, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 235, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 236, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 238, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 238, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 238, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 238, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 239, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 241, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 241, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 241, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 241, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 242, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 244, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 244, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 244, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 244, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 245, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 247, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 247, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 247, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 247, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 248, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 250, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 250, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 250, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 250, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 251, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 253, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 253, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 253, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 253, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 254, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 256, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 256, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 256, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 11, record 256, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 1, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 1, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 3, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 3, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 3, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 3, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 3, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 5, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 5, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 5, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 5, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 5, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 7, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 7, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 7, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 7, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 7, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 9, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 9, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 9, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 9, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 9, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 11, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 11, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 11, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 11, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 11, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 13, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 13, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 13, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 13, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 13, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 15, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 15, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 15, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 15, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 15, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 17, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 17, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 17, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 17, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 17, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 18, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 18, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 18, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 19, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 19, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 19, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 19, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 19, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 21, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 21, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 21, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 21, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 21, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 23, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 23, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 23, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 23, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 23, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 25, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 25, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 25, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 25, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 25, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 27, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 27, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 27, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 27, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 27, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 29, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 29, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 29, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 29, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 29, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 31, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 31, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 31, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 31, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 31, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 33, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 33, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 33, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 33, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 33, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 35, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 35, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 35, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 35, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 35, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 37, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 37, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 37, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 37, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 37, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 39, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 39, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 39, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 39, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 39, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 41, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 41, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 41, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 41, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 41, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 43, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 43, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 43, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 43, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 43, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 45, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 45, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 45, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 45, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 45, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 47, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 47, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 47, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 47, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 47, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 49, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 49, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 49, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 49, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 49, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 51, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 51, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 51, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 51, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 51, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 52, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 52, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 52, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 53, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 53, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 53, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 53, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 53, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 55, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 55, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 55, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 55, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 55, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 57, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 57, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 57, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 57, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 57, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 59, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 59, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 59, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 59, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 59, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 61, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 61, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 61, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 61, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 61, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 62, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 62, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 62, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 63, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 63, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 63, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 63, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 63, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 65, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 65, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 65, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 65, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 65, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 67, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 67, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 67, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 67, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 67, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 69, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 69, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 69, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 69, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 69, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 71, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 71, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 71, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 71, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 71, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 73, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 73, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 73, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 73, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 73, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 75, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 75, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 75, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 75, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 75, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 77, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 77, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 77, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 77, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 77, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 79, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 79, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 79, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 79, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 79, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 81, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 81, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 81, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 81, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 81, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 83, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 83, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 83, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 83, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 83, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 85, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 85, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 85, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 85, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 85, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 87, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 87, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 87, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 87, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 87, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 89, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 89, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 89, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 89, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 89, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 91, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 91, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 91, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 91, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 91, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 93, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 93, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 93, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 93, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 93, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 95, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 95, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 95, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 95, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 95, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 97, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 97, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 97, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 97, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 97, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 99, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 99, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 99, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 99, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 99, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 100, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 100, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 100, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 101, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 101, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 101, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 101, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 101, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 103, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 103, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 103, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 103, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 103, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 105, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 105, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 105, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 105, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 105, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 107, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 107, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 107, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 107, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 107, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 109, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 109, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 109, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 109, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 109, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 111, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 111, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 111, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 111, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 111, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 113, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 113, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 113, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 113, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 113, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 115, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 115, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 115, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 115, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 115, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 117, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 117, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 117, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 117, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 117, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 119, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 119, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 119, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 119, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 119, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 121, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 121, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 121, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 121, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 121, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 123, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 123, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 123, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 123, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 123, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 125, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 125, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 125, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 125, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 125, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 127, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 127, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 127, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 127, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 127, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 129, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 129, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 129, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 129, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 129, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 131, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 131, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 131, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 131, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 131, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 133, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 133, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 133, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 133, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 133, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 135, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 135, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 135, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 135, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 135, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 137, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 137, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 137, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 137, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 137, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 139, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 139, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 139, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 139, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 139, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 141, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 141, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 141, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 141, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 141, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 143, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 143, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 143, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 143, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 143, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 145, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 145, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 145, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 145, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 145, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 147, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 147, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 147, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 147, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 147, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 149, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 149, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 149, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 149, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 149, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 151, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 151, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 151, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 151, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 151, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 153, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 153, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 153, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 153, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 153, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 155, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 155, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 155, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 155, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 155, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 157, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 157, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 157, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 157, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 157, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 159, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 159, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 159, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 159, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 159, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 161, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 161, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 161, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 161, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 161, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 163, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 163, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 163, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 163, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 163, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 165, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 165, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 165, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 165, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 165, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 167, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 167, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 167, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 167, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 167, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 168, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 168, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 168, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 169, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 169, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 169, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 169, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 169, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 171, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 171, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 171, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 171, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 171, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 173, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 173, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 173, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 173, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 173, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 175, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 175, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 175, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 175, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 175, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 176, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 176, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 176, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 177, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 177, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 177, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 177, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 177, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 179, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 179, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 179, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 179, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 179, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 181, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 181, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 181, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 181, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 181, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 183, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 183, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 183, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 183, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 183, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 185, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 185, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 185, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 185, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 185, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 187, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 187, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 187, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 187, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 187, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 189, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 189, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 189, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 189, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 189, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 191, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 191, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 191, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 191, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 191, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 193, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 193, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 193, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 193, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 193, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 195, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 195, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 195, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 195, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 195, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 197, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 197, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 197, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 197, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 197, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 199, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 199, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 199, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 199, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 199, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 201, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 201, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 201, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 201, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 201, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 203, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 203, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 203, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 203, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 203, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 205, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 205, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 205, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 205, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 205, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 207, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 207, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 207, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 207, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 207, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 209, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 209, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 209, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 209, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 209, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 211, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 211, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 211, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 211, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 211, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 213, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 213, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 213, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 213, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 213, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 215, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 215, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 215, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 215, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 215, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 217, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 217, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 217, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 217, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 217, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 219, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 219, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 219, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 219, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 219, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 221, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 221, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 221, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 221, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 221, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 223, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 223, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 223, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 223, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 223, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 225, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 225, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 225, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 225, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 225, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 227, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 227, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 227, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 227, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 227, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 229, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 229, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 229, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 229, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 229, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 231, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 231, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 231, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 231, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 231, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 233, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 233, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 233, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 233, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 233, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 235, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 235, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 235, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 235, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 235, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 237, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 237, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 237, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 237, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 237, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 239, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 239, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 239, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 239, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 239, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 241, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 241, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 241, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 241, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 241, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 243, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 243, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 243, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 243, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 243, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 245, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 245, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 245, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 245, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 245, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 247, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 247, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 247, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 247, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 247, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 249, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 249, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 249, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 249, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 249, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 251, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 251, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 251, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 251, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 251, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 253, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 253, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 253, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 253, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 253, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 255, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 255, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 255, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 255, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 13, record 255, field 6: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 1, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 1, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 3, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 3, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 5, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 5, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 7, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 7, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 9, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 9, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 11, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 11, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 13, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 13, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 15, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 15, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 17, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 17, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 19, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 19, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 21, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 21, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 23, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 23, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 25, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 25, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 27, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 27, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 29, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 29, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 31, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 31, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 33, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 33, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 35, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 35, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 37, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 37, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 39, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 39, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 41, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 41, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 43, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 43, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 45, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 45, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 47, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 47, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 49, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 49, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 51, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 51, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 53, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 53, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 55, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 55, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 57, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 57, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 59, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 59, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 61, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 61, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 63, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 63, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 65, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 65, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 67, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 67, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 69, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 69, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 71, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 71, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 73, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 73, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 75, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 75, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 77, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 77, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 79, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 79, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 81, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 81, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 83, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 83, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 85, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 85, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 87, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 87, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 89, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 89, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 91, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 91, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 93, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 93, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 95, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 95, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 97, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 97, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 99, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 99, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 101, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 101, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 103, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 103, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 105, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 105, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 107, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 107, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 109, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 109, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 111, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 111, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 113, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 113, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 115, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 115, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 117, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 117, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 119, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 119, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 121, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 121, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 123, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 123, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 125, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 125, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 127, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 127, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 129, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 129, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 131, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 131, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 133, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 133, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 135, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 135, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 137, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 137, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 139, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 139, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 141, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 141, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 143, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 143, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 145, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 145, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 147, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 147, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 149, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 149, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 151, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 151, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 153, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 153, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 155, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 155, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 157, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 157, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 159, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 159, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 161, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 161, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 163, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 163, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 165, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 165, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 167, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 167, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 169, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 169, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 171, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 171, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 173, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 173, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 175, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 175, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 177, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 177, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 179, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 179, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 181, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 181, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 183, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 183, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 185, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 185, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 187, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 187, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 189, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 189, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 191, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 191, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 193, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 193, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 195, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 195, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 197, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 197, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 199, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 199, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 201, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 201, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 203, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 203, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 205, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 205, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 207, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 207, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 209, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 209, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 211, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 211, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 213, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 213, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 215, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 215, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 217, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 217, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 219, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 219, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 221, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 221, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 223, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 223, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 225, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 225, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 227, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 227, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 229, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 229, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 231, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 231, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 233, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 233, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 235, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 235, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 237, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 237, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 239, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 239, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 241, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 241, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 243, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 243, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 245, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 245, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 247, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 247, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 249, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 249, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 251, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 251, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 253, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 253, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 255, field 1: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 15, record 255, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 1, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 1, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 1, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 2, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 3, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 3, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 3, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 4, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 5, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 5, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 5, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 6, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 7, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 7, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 7, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 8, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 9, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 9, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 9, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 10, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 11, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 11, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 11, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 12, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 13, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 13, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 13, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 14, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 15, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 15, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 15, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 16, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 17, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 17, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 17, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 18, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 19, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 19, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 19, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 20, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 21, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 21, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 21, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 22, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 23, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 23, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 23, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 24, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 25, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 25, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 25, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 26, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 27, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 27, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 27, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 28, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 29, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 29, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 29, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 30, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 31, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 31, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 31, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 32, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 33, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 33, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 33, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 34, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 35, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 35, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 35, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 36, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 37, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 37, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 37, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 38, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 39, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 39, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 39, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 40, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 41, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 41, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 41, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 42, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 43, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 43, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 43, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 44, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 45, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 45, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 45, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 46, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 47, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 47, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 47, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 48, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 49, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 49, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 49, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 50, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 51, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 51, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 51, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 52, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 53, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 53, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 53, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 54, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 55, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 55, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 55, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 56, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 57, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 57, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 57, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 58, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 59, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 59, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 59, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 60, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 61, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 61, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 61, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 62, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 63, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 63, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 63, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 64, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 65, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 65, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 65, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 66, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 67, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 67, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 67, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 68, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 69, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 69, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 69, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 70, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 71, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 71, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 71, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 72, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 73, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 73, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 73, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 74, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 75, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 75, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 75, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 76, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 77, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 77, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 77, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 78, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 79, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 79, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 79, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 80, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 81, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 81, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 81, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 82, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 83, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 83, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 83, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 84, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 85, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 85, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 85, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 86, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 87, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 87, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 87, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 88, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 89, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 89, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 89, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 90, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 91, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 91, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 91, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 92, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 93, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 93, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 93, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 94, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 95, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 95, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 95, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 96, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 97, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 97, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 97, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 98, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 99, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 99, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 99, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 100, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 101, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 101, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 101, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 102, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 103, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 103, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 103, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 104, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 105, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 105, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 105, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 106, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 107, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 107, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 107, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 108, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 109, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 109, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 109, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 110, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 111, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 111, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 111, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 112, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 113, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 113, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 113, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 114, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 115, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 115, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 115, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 116, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 117, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 117, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 117, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 118, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 119, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 119, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 119, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 120, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 121, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 121, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 121, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 122, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 123, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 123, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 123, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 124, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 125, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 125, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 125, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 126, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 127, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 127, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 127, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 128, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 129, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 129, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 129, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 130, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 131, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 131, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 131, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 132, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 133, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 133, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 133, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 134, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 135, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 135, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 135, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 136, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 137, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 137, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 137, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 138, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 139, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 139, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 139, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 140, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 141, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 141, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 141, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 142, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 143, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 143, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 143, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 144, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 145, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 145, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 145, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 146, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 147, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 147, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 147, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 148, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 149, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 149, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 149, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 150, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 151, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 151, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 151, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 152, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 153, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 153, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 153, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 154, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 155, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 155, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 155, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 156, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 157, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 157, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 157, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 158, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 159, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 159, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 159, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 160, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 161, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 161, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 161, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 162, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 163, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 163, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 163, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 164, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 165, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 165, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 165, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 166, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 167, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 167, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 167, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 168, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 169, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 169, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 169, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 170, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 171, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 171, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 171, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 172, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 173, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 173, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 173, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 174, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 175, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 175, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 175, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 176, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 177, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 177, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 177, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 178, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 179, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 179, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 179, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 180, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 181, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 181, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 181, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 182, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 183, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 183, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 183, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 184, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 185, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 185, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 185, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 186, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 187, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 187, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 187, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 188, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 189, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 189, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 189, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 190, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 191, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 191, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 191, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 192, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 193, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 193, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 193, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 194, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 195, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 195, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 195, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 196, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 197, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 197, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 197, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 198, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 199, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 199, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 199, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 200, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 201, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 201, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 201, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 202, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 203, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 203, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 203, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 204, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 205, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 205, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 205, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 206, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 207, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 207, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 207, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 208, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 209, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 209, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 209, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 210, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 211, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 211, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 211, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 212, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 213, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 213, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 213, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 214, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 215, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 215, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 215, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 216, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 217, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 217, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 217, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 218, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 219, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 219, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 219, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 220, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 221, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 221, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 221, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 222, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 223, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 223, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 223, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 224, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 225, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 225, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 225, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 226, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 227, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 227, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 227, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 228, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 229, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 229, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 229, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 230, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 231, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 231, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 231, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 232, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 233, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 233, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 233, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 234, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 235, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 235, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 235, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 236, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 237, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 237, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 237, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 238, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 239, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 239, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 239, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 240, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 241, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 241, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 241, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 242, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 243, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 243, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 243, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 244, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 245, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 245, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 245, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 246, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 247, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 247, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 247, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 248, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 249, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 249, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 249, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 250, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 251, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 251, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 251, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 252, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 253, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 253, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 253, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 254, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 255, field 2: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 255, field 3: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 255, field 4: Value does not match its data type 'IEEE754MSBDouble': NaN is not allowed
      ERROR  [error.table.field_value_data_type_mismatch]   data object 19, record 256, field 4: Value does not match its data type 'IEEE754MSBDouble': Infinity is not allowed
    End Content Validation: file:/V:/stage/m2020/aawork/SUPERCAM/validation/troubleshooting/product/scam_0072_0673327336_185_cp2_scam01072_scct_41_irsalign_____04p04.fits
        1 product validation(s) completed

Summary:

  1553 error(s)
  0 warning(s)

  Product Validation Summary:
    0          product(s) passed
    1          product(s) failed
    0          product(s) skipped

  Referential Integrity Check Summary:
    0          check(s) passed
    0          check(s) failed
    0          check(s) skipped

  Message Types:
    1552         error.table.field_value_data_type_mismatch
    1            error.label.invalid_object_definition

End of Report